Table 3 - Electrical data
50TZ (40TZ/BZ + 38BZ) 024 036 042 048 060 072 084
Nominal voltage (± 10%)* V 230 400 230 400 230 400 230 400 230 400 230 400 230 400
Nominal power input** kW 2.90 2.90 3.99 3.99 4.68 4.68 5.07 5.07 7.37 7.37 10.08 10.08 10.75 10.75
Nominal current drawn** A 13.33 6.30 12.50 8.74 15.58 11.50 16.98 12.23 25.49 18.54 30.12 17.41 33.19 19.18
Effective power input kW 2.90 2.90 3.89 3.89 4.54 4.54 4.93 4.93 6.96 6.96 9.39 9.39 9.99 9.99
Effective current drawn A 13.33 6.30 12.19 8.52 15.11 11.16 16.51 11.89 24.07 17.51 28.06 16.22 30.67 17.73
Starting current A 86 46 99 60 117 72 134 81 159 105 170 90 162 105
Maximum power input*** kW 3.24 3.24 4.53 4.53 5.23 5.23 5.71 5.71 8.00 8.00 10.74 10.74 11.95 11.95
Maximum current drawn*** A 14.88 7.04 14.19 9.92 17.42 12.86 19.13 13.78 27.67 20.13 32.09 18.55 35.93 20.77
* The unit power supply is three phase (except size 024, 230 V, which is single-phase). The fan power supply is single phase, except for sizes 072 and 084 which are three phase.
** Based on an outdoor air dry bulb temperature of 35°C and an indoor temperature of 19°C wet bulb and 27°C dry bulb.
*** Based on an outdoor air dry bulb temperature of 46°C and an indoor air wet bulb temperature of 21°C.
Note: The effective power input is according to EUROVENT.
Condensing unit 38FZ 024 036 042 048 060 072 084
Nominal voltage (± 10%)* V 230 400 230 400 230 400 230 400 230 400 230 400 230 400
Nominal power input** kW 2.45 2.45 3.63 3.63 4.04 4.04 4.51 4.51 6.49 6.49 8.52 8.52 9.16 9.16
Nominal current drawn** A 11.25 5.32 11.37 7.95 13.45 9.93 15.11 10.89 22.45 16.33 25.46 14.72 28.27 16.34
Effective power input kW 2.45 2.45 3.63 3.63 4.04 4.04 4.51 4.51 6.26 6.26 8.24 8.24 8.85 8.85
Effective current drawn A 11.26 5.32 11.38 7.95 13.45 9.93 15.10 10.88 21.65 15.75 24.62 14.23 27.31 15.79
Starting current A 84.6 44.6 97.1 58.1 114.6 69.6 131.6 78.6 154.8 100.8 166.5 88.0 157.2 102.2
Maximum power input*** kW 3.02 3.02 4.14 4.14 4.66 4.66 5.38 5.38 7.60 7.60 10.06 10.06 10.75 10.75
Maximum current drawn*** A 13.9 6.6 13.0 9.1 15.5 11.5 18.0 13.0 26.3 19.1 30.1 17.4 33.19 19.18
* The unit power supply is three phase (except size 024, 230 V, which is single-phase). The fan power supply is single phase, except for sizes 072 and 084 which are three phase.
** Based on an outdoor air dry bulb temperature of 35°C and a dewpoint suction temperature of 7°C.
*** Based on an outdoor air dry bulb temperature of 46°C and a dewpoint suction temperature of 12°C.
Note: The effective power input is according to EUROVENT.
Table 4 - Electrical data
50YZ (40BZ + 38BZ) 024 036 042 048 060 072 084
Nominal voltage (± 10%)* V 230 400 230 400 230 400 230 400 230 400 230 400 230 400
Nominal power input kW
Cooling** 2.74 2.74 4.20 4.20 4.70 4.70 5.04 5.04 7.57 7.57 10.10 10.10 10.92 10.92
Heating*** 2.35 2.35 3.51 3.51 4.00 4.00 4.55 4.55 6.97 6.97 9.07 9.07 9.58 9.58
Nominal current drawn A
Cooling** 12.77 6.04 13.89 10.06 15.79 11.40 17.10 12.43 25.29 18.06 30.00 17.34 33.65 19.45
Heating*** 11.21 5.30 12.00 8.87 14.14 10.60 15.76 11.65 24.09 17.57 27.59 15.95 30.79 17.80
Effective power input kW
Cooling 2.74 2.74 4.10 4.10 4.56 4.56 4.90 4.90 7.16 7.16 9.41 9.41 10.16 10.16
Heating 2.35 2.35 3.41 3.41 3.86 3.86 4.41 4.41 6.56 6.56 8.38 8.38 8.82 8.82
Effective current drawn A
Cooling 12.76 6.04 13.56 9.82 15.32 11.06 16.63 12.09 23.92 17.08 27.96 16.16 31.14 18.00
Heating 11.20 5.30 11.66 8.62 13.65 10.23 15.28 11.30 22.68 16.54 25.50 14.74 28.28 16.35
Starting current A 86 46 99 60 117 72 134 81 159 105 170 90 162 105
Maximum power input*** kW
Cooling**** 3.08 3.08 4.65 4.65 5.22 5.22 5.66 5.66 8.26 8.26 11.06 11.06 12.04 12.04
Heating***** 2.78 2.78 4.07 4.07 4.63 4.63 5.09 5.09 7.70 7.70 10.54 10.54 11.87 11.87
Maximum current drawn*** A
Cooling**** 14.17 6.70 14.86 10.54 17.24 12.28 18.23 12.91 27.10 19.03 32.87 19.00 35.94 20.78
Heating***** 12.79 6.05 13.01 9.23 15.29 10.89 16.39 11.61 25.26 17.74 31.32 18.11 35.44 20.48
* The unit power supply is three phase (except size 024, 230 V, which is single-phase). The fan power supply is single phase, except for sizes 072 and 084 which are three phase.
** Based on an outdoor air dry bulb temperature of 35°C and an indoor temperature of 19°C wet bulb.
*** Based on an outdoor air wet bulb temperature of 6°C and an indoor temperature of 20°C dry bulb.
**** Based on an outdoor air dry bulb temperature of 46°C and an indoor air wet bulb temperature of 21°C.
***** Based on an outdoor air wet bulb temperature of 18°C.
Note: The effective power input is according to EUROVENT.