32
PERFORMANCE AND ELECTRICAL DATA (CONT.)
MODEL 52ME (230/208 -- 1--60)
MODEL
NUMBER
52ME
CAPACITY
EER COP
VOLTAGE
RANGE
COOLING
Cooling
Heating
AMPS WATTS
Rev. Cyc. Electic
U 0 7 --- --- --- 3 --- ---
SEE POWER
CORD
SELECTION
GUIDE
BELOW
--- ---
187 --- 253
--- ---
U 0 9 --- --- --- 3 8800 / 9000 --- 11.4 / 11.4 --- 3.9 / 3.7 770 / 790
U 1 2 --- --- --- 3 12,000 / 12,100 --- 11.4 / 11.5 --- 5/ 4.7 1060 / 1070
U 1 5 --- --- --- 3 --- --- --- --- --- ---
MODEL
NUMBER
52ME
POWER
FACTOR
(%)
FAN MOTOR
R --- 2 2
CHARGE
(OZ)
DEHUM.
(Pint/Hr)
SENSIBLE
HEAT
FACTOR
APPROX.
CHASSIS
SHIP WT.
(lb)
Indoor
Motor
HP
Indoor
Motor
Full Load
Amps
Indoor CFM
Out-
door
Motor
HP
Outdoor
Motor
Full Load
Amps
Low Med High
U 0 7 --- --- --- 3 --- --- --- --- --- --- --- --- --- --- --- 125
U 0 9 --- --- --- 3 98 0.029 0.2 265 290 330 0.088 0.6 28.9 2.9 0.73 125
U 1 2 --- --- --- 3 100 0.029 0.2 280 300 320 0.088 0.6 36.0 3.9 0.71 140
U 1 5 --- --- --- 3 --- --- --- --- --- --- --- --- --- --- --- 150
LEGEND
EER — Energy Ef f iciency Ratio
* Rated in accordance with ARI Standard 380-93.
† Fan motor indoor CFM (LO/HI) shown for 230-1-60 u nits.
POWER CORD SELECTION GUIDE
52M PTACs are not individually equipped with a power cord, so one must be ordered separately
based on the voltage and ampeage of your electrical circuit. If the unit is to be plugged into a
receptacle, then a line cord connection kit needs to be selected. If it will be permanently connnected,
a hardwire connection must be used.
Model No. Voltage Re ceptacle Type
Heating
(BTUH)
Heater
(Kw)
Input Power
Current
(Amps)
Branch Cir-
ciut Full
Amps
PWRCORD---230V ---15A
208/230V
15 amp /250 5631 / 6949 2 1650 / 2036 11.3 15
PWRCORD---230V ---20A 20 a mp /250
8556 /
10393
3 2507/ 3045 17.3 20
P W R C OR D --- 2 3 0 --- 3 0 A 30 a mp /250
13778 /
16990
5 4037 / 4978 27.1 30
RECEPTACLE AND FUSE TYPES
UNIT NAMEPLATE VOLTAGE 230/208
OUTLET RATED VOLTS/AMPS 250/15 250/20 250/30
OUTLET BLADE CONFIGURATION
RECEPTACLE TYPE A B C
NEMA CONFIGURATION 6 --- 1 5 R 6 --- 2 0 R 6 --- 3 0 R
TIMEDEALYFUSEORHACRCIRCUITBREAKER(AMPS) 15 20* 30
LEGEND
HACR --- Heating, Air Conditioning, and Refrigeration
NEMA --- National Electrical Manufacturers Association
* May be used for 15---amp applications if fu sed for 15 amps.
New York City Department of Buildings, Material
and Equipment Acceptance — MEA #------ ---- --
52M