Refrigerant | R410A |
---|---|
Cooling Capacity | 12000 BTU/h |
Noise Level (Outdoor) | 52 dB |
Weight (Indoor Unit) | 9 kg |
Weight (Outdoor Unit) | 32 kg |
General safety guidelines during installation and maintenance.
Conditions not covered by the product warranty.
Details of split system models for different sizes.
Explanation of model codes and their components.
Specifies operational temperature ranges and power supply voltage.
Guidelines for choosing an optimal indoor unit installation location.
Recommended and avoided locations for outdoor unit placement.
Factors to consider when selecting an outdoor unit installation location.
Specifies minimum space requirements around a single outdoor unit.
Specifies minimum space requirements for serial installation of multiple outdoor units.
Items to verify for the indoor unit installation location.
Items to verify for the outdoor unit installation location.
Items to verify for refrigerant piping connections.
Lists accessories provided with the unit for installation.
Lists additional accessories for export markets.
Lists accessories not supplied but required for installation.
Steps for preparing the wall for indoor unit installation.
Guidelines for drilling the wall hole for unit connections.
Instructions for mounting the wall hang bracket for the indoor unit.
Steps to attach and secure the indoor unit onto the installed wall bracket.
Guide on how to install batteries into the remote control.
Instructions and tips for using the wireless remote control effectively.
Steps for preparing the outdoor unit before installation.
Instructions for assembling and installing the wall support for the outdoor unit.
Chart illustrating the sequence of refrigerant piping connections.
Details on the four possible outlet locations for refrigerant piping from the indoor unit.
Guidelines for proper bending, connection, and material selection for refrigerant piping.
Data on maximum refrigerant piping lengths and vertical distances.
Table specifying pipe diameters and maximum lengths for different models.
Instructions for calculating additional refrigerant charge based on piping length.
Diagrams identifying refrigerant connection points on outdoor units.
Diagrams identifying refrigerant connection points on indoor units.
Identification of gas and liquid piping lines.
Tools required for preparing refrigerant piping lines.
Procedures for cutting and removing burrs from refrigerant piping.
Method for flaring refrigerant pipe ends using a flare tool.
Steps for removing protective plastic nuts from unit connections.
Instructions for attaching flare nuts to refrigerant piping ends.
Steps for connecting refrigerant lines to the indoor unit.
Steps for connecting refrigerant lines to the outdoor unit.
Importance and effects of air in the refrigerant system.
Procedure for purging air using the system's contained refrigerant.
Steps for using a vacuum pump to purge air from the system.
Steps to collect refrigerant back into the outdoor unit before disconnection.
Procedures for checking refrigerant leaks using soapy water or a detector.
Guidelines for insulating piping to prevent condensation and conserve energy.
Specifications for the condensate drain line material and diameter.
Possible positions for routing the drain line from the indoor unit.
Instructions for proper drain line installation, avoiding traps and kinks.
Guidelines for wiring between the power supply and the air conditioner circuit breaker.
Instructions for connecting indoor, outdoor units, and the circuit breaker.
Table detailing electrical consumption and circuit breaker ratings for models.
Steps before wiring the outdoor unit.
Specific wiring instructions for heat pump systems.
Wiring details for outdoor units in heat pump systems.
Wiring details for indoor units in heat pump systems.
Wiring diagrams for cool-only models in the 12K-18K range.
Wiring diagrams for heat pump models in the 12K-18K range.
Wiring diagrams for 24K models (cool only and heat pump).
Tasks to complete after major installation, such as tidying cables and sealing.
Checks to perform before starting the test run.
Procedure for initiating a cooling test using the unit's manual control.
Detailed steps for performing a cooling test run.
Detailed steps for performing a heating test run.
How to control air supply direction using louvers.
Using the remote to adjust vertical airflow direction.
Activating the automatic swing function for horizontal louvers.
Manual and automatic adjustment of horizontal louvers.
Checklist items for the indoor unit installation.
Checklist items for the outdoor unit installation.
Checklist for refrigerant piping connections.
Checklist for the condensate drain line.
Checklist for electrical connections.
Verifying tidiness and sealing after installation.
Checks related to unit operation and noise during testing.
Ensuring customer operation explanation and manual handover.
Table of malfunctions and corresponding LED indicators for cool-only models.
Table of malfunctions and LED indicators for heat pump models.