EasyManua.ls Logo

Carrier ClassiCOOL 53KDHT60N-518 User Manual

Carrier ClassiCOOL 53KDHT60N-518
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Rev. (0) - 2014
Rev. (0) - 2016
Enviromental
Management System
ISO 14001 : 2004
Certicate No : 12 104 30334 TMS
Safety
Management System
BS OHSAS 18001 : 2007
Certicate No : 12 116 30334 TMS
53KDHT60N-518
53KDHT72N-518
53KDHT84N-518
53KDHT90N-518
03504154
I N S T A L L A T I O N M A N U A L
Miraco
Miraco
MISR REFRIGERATION & AIR CONDITIONING MFG. CO.
380-420V ~ 50Hz 3Ph
Carrier is committed for continuous improvement of Carrier products according to national and international standards
to ensure the highest quality and reliability standards, and to meet market regulations and requirements.
All specications subject to change without prior notice according to Carrier policy of continuous development.
Ceiling Concealed Ducted Split Systems
High Efciency - Green
Cool Only
Question and Answer IconNeed help?

Do you have a question about the Carrier ClassiCOOL 53KDHT60N-518 and is the answer not in the manual?

Carrier ClassiCOOL 53KDHT60N-518 Specifications

General IconGeneral
BrandCarrier
ModelClassiCOOL 53KDHT60N-518
CategoryAir Conditioner
LanguageEnglish

Summary

General Notes and Installation Precautions

Installation Tools Required

Lists the essential tools needed for the installation process.

Key Installation and Operation Notes

Highlights important steps during installation and customer guidance.

Safety Precautions for Installation

Outlines critical safety measures and warnings for safe installation.

System Overview and Unit Specifications

Ducted Split System Description

Provides a description and diagram of the ducted split system.

Unit Models and Identification

Explains unit models and the system's identification coding.

Operating Limits and Power Supply

Specifies cooling operating limits and main power supply requirements.

Unit Dimensions and Location Selection

Indoor Unit Dimensions and Weight

Details the dimensions and weight of the indoor unit.

Outdoor Unit Dimensions and Weight

Details the dimensions and weight of the outdoor unit.

Indoor Unit Installation Location

Guides on selecting an appropriate installation location for the indoor unit.

Outdoor Unit Installation Location

Guides on selecting an appropriate installation location for the outdoor unit.

Outdoor Unit Installation Clearances

Single Outdoor Unit Clearances

Details minimum clearances for single outdoor unit installation.

Multiple Outdoor Unit Clearances (Series)

Details minimum clearances for serial installation of multiple outdoor units.

Installation Checklists and Accessories

Installation Location Checklist

Checklist items for verifying installation location suitability.

Installation Accessories

Lists standard and other required installation accessories.

Indoor Unit Installation Procedures

Indoor Unit Preparation Steps

Covers wall hole preparation and sleeve installation.

Hanging Bolts and Unit Mounting

Details installing hanging bolts and mounting the indoor unit.

Indoor Unit Duct Installation

Illustrates and describes recommended duct connections for the indoor unit.

Wired Room Controller Installation

Controller Safety and Precautions

Safety warnings and other precautions for installing the wired controller.

Controller Installation Diagram and Wiring

Provides wiring diagrams and steps for controller installation.

Controller Initial Parameter Setting

Explains how to set initial parameters for the wired remote controller.

Display and Receiver Panel Installation

Display Panel Description

Describes the components of the display and receiver panel.

Panel Installation (No Wireless Remote)

Details installation when not using an optional wireless remote control.

Panel Installation (With Wireless Remote)

Details installation of the display panel for use with a wireless remote.

Outdoor Unit Installation Procedures

Outdoor Unit Preparation Steps

Outlines preparation steps before installing the outdoor unit.

Outdoor Unit Floor Installation

Describes floor installation steps for the outdoor unit.

Refrigerant Piping Lines: R410A and Connections

R410A Refrigerant Quick Reference

Key information and precautions for R410A refrigerant.

Refrigerant Connection Steps Overview

Outlines the chart and instructions for refrigerant pipe connections.

Piping Bending and Coiling

Details proper techniques for bending and coiling refrigerant pipes.

Refrigerant Piping Use Guidance

Guidance on using refrigerant piping based on unit placement and length.

Refrigerant Charge Calculation

Details how to add refrigerant for longer piping lines and notes.

Refrigerant Piping Preparation and Connection

Outdoor Unit Connection Ports

Identifies refrigerant connection ports on the outdoor unit.

Indoor Unit Connection Ports

Identifies refrigerant connection ports on the indoor unit.

Preparing Piping Lines (Cutting & Flaring)

Steps for cutting and flaring refrigerant piping lines.

Mounting Flare Nuts on Piping

Details removing protective nuts and mounting flare nuts.

Connecting Piping to Indoor & Outdoor Units

Explains connecting piping to indoor and outdoor units with torque specs.

System Purging and Pumping Down

Air Purging Using Vacuum Pump

Step-by-step procedure for air purging with a vacuum pump.

Pumping Down for Re-installation

Explains the process of pumping down refrigerant for relocation or repair.

Leak Checking and Pipe Insulation

Refrigerant Leak Check Methods

Describes methods for checking refrigerant leaks after connection.

Insulating Refrigerant Piping Lines

Provides instructions for insulating refrigerant piping lines.

Drain Line Installation and Testing

Drain Line Installation (Without Pump)

Details installing the drain line for units without an optional drain pump.

Drainage Test (Without Pump)

Explains how to perform a drainage test for units without a pump.

Drain Line Installation (With Optional Pump)

Details installing the drain line for units with an optional drain pump.

Drainage Test (With Optional Pump)

Explains how to perform a drainage test for units with a pump.

Electrical Wiring and Data

Wiring Power Supply to Circuit Breaker

Covers electrical wiring from power supply to the circuit breaker.

Wiring Between Units and Circuit Breaker

Details electrical wiring between units and the main power supply.

Electrical Data and Outdoor Unit Connections

Provides electrical data and connection procedures for the outdoor unit.

Field Wiring Diagrams

Shows wiring diagrams for indoor/outdoor units and power supply.

Setting Indoor Unit Switches

Setting Static Pressure Range (ENC2)

Explains how to set the static pressure range using switch ENC2.

Finishing Installation Steps

Final Installation Steps

Details the final steps to complete the installation process.

Test Running Procedures

Notes for Test Running

Important notes to consider before conducting the test run.

Cooling Test Running Procedure

Step-by-step guide for performing the cooling test run.

Post-Installation Verification

Unit and Piping Connection Checks

Checklist for indoor/outdoor units and refrigerant piping connections.

Drain and Electrical Connection Checks

Checklist for drain line and electrical connections.

Finishing and Test Running Checks

Checklist for finishing installation and test running.

Customer Guidance Points

Key points for customer explanation and manual handover.

Malfunction Detection and Diagnostics

Indoor Unit Self-Diagnostic Function

Explains the self-diagnostic function and error codes for indoor units.

Display Panel Malfunction Codes

Details malfunction reasons and LED indicators on the display panel.

Outdoor Unit PCB Malfunction Codes

Lists LED status codes and malfunction reasons for the outdoor unit PCB.