Select installation location which allows the minimum clearances shown in the figures for free 
air circulation and easy accessibility for service and maintenance : 
 
  The front of outdoor unit ( air outlet )  
should be away from any obstacle by 500 mm or more to ensure free air circulation. 
 
  The back of outdoor unit ( air inlet ) 
should be away from any obstacle by 160 mm or more. This distance is built in the design of wall support 
to ensure free air circulation. 
 
  The left side of outdoor unit  
should by away from any obstacle by 400 mm or more to ensure easy access to refrigerant and electrical 
connections. 
 
  The right side of outdoor unit ( air inlet ) 
should be away from any obstacle by 250 mm or more to ensure free air circulation. 
 
  The top side of outdoor unit  
should be away from any obstacle by 400 mm or more to ensure easy access to the electrical 
components, motor and fan.