53KHET24-708F 42KHET24-708F 38KHET24-708
Notes:
53 = Split System
42 = Indoor Unit
38 = Outdoor Unit
Q = Heat Pump
K = Cool Only
H = Hi Wall System
E = Elite Series
T = High Ambient
12 = System Size
7 = Nominal Power Supply 220-240V~ 50Hz 1Ph
0 = Wireless Remote Control
8 = Miraco – Carrier
F = Ionizer
5. OPERATING LIMITS *
COOLING
HEATING
Difference
Dry Bulb
Temp. C°
Wet Bulb
Temp. C°
Difference
Dry Bulb
Temp. C°
Wet Bulb
Temp. C°
Indoor temperature
Maximum
Minimum
32
21
23
15
Indoor temperature
Maximum
Minimum
27
20
Outdoor temperature
Maximum
Minimum
52
21
Outdoor temperature
Maximum
Minimum
24
2
18
1
MAIN POWER SUPPLY
Nominal
220-240V~ 50Hz 1Ph
Min. Voltage 198
Max. Voltage 254
NOTES:
* When the system is operated above or below these limits for a long time, system
diagnostics may detect a malfunction and the system will not operate properly.
** During heat pump operation, the system will undergo several defrost cycles to eliminate ice
that might possibly collect on the outdoor unit in very low ambient temperatures.
After completion of defrost cycle, the system will normally operate