EasyManua.ls Logo

Carrier 58CTA, 58CTX - Dimensions

Carrier 58CTA, 58CTX
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
DIMENSIONS
A
A
B
[736.9]
[736.9]
29
29
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY
ACCESSORY
5 15/16
5 15/16
[150.7]
[150.7]
28.39
28.39
[721.2]
[721.2]
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY
ACCESSORY
14 7/8
14 7/8
[337.3]
[337.3]
(BOTH SIDES)
(BOTH SIDES)
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY
ACCESSORY
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY
ACCESSORY
Ø1 3/4
Ø1 3/4
[44.5]
[44.5]
GAS ENTRY
GAS ENTRY
Ø1/2
Ø1/2
[12.7]
[12.7]
THERMOSTAT WIRE ENTRY
THERMOSTAT WIRE ENTRY
22 1/16
22 1/16
[560]
[560]
SIDE INLET
SIDE INLET
(BOTH SIDES)
(BOTH SIDES)
11 7/16
11 7/16
[290.7]
[290.7]
9 11/16
9 11/16
[245.4]
[245.4]
[197.8]
[197.8]
7 13/16
7 13/16
Ø7/8
Ø7/8
[22.2]
[22.2]
J.BOX PROVISION
J.BOX PROVISION
Ø7/8
Ø7/8
[22.2]
[22.2]
JUNCTION BOX
JUNCTION BOX
LOCATION
LOCATION
Ø1 3/4
Ø1 3/4
[44.5]
[44.5]
GAS ENTRY
GAS ENTRY
1 15/16
1 15/16
[49.2]
[49.2]
1
[25.4]
[25.4]
1 1/4
1 1/4
[31.8]
[31.8]
29 9/16
29 9/16
[750.7]
[750.7]
1 15/16
1 15/16
[49.2]
[49.2]
5 5/8
5 5/8
[143.3]
[143.3]
5 7/16
5 7/16
[138.5]
[138.5]
6 13/16
6 13/16
[172.3]
[172.3]
Ø1/2
Ø1/2
[12.7]
[12.7]
THERMOSTAT WIRE ENTRY
THERMOSTAT WIRE ENTRY
19
19
[481.7]
[481.7]
OUTLET
OUTLET
D
21.6
21.6
[549.5]
[549.5]
BOTTOM INLET
BOTTOM INLET
C
33 1/4
33 1/4
[843.9]
[843.9]
9 9/16
9 9/16
[243.3]
[243.3]
3/4
3/4
[19.1]
[19.1]
5 7/8
5 7/8
[148.5]
[148.5]
3 7/16
3 7/16
[86.8]
[86.8]
9 7/8
9 7/8
[250.7]
[250.7]
27 3/4
27 3/4
[704.7]
[704.7]
2 5/16
2 5/16
[59]
[59]
FRONT OF CASING
FRONT OF CASING
TOP OF CASING
TOP OF CASING
4 13/16
4 13/16
[122.2]
[122.2]
27 3/4
27 3/4
[704.7]
[704.7]
5 7/8
5 7/8
[148.5]
[148.5]
8 5/8
8 5/8
[219]
[219]
5 1/2
5 1/2
[140.3]
[140.3]
8 7/16
8 7/16
[213.5]
[213.5]
FRONT OF CASING
FRONT OF CASING
TOP OF CASING
TOP OF CASING
6.1
6.1
[155.7]
[155.7]
2 1/16
2 1/16
[51.6]
[51.6]
5.1
5.1
[130.5]
[130.5]
1.7
1.7
[43.5]
[43.5]
Ø7/8
Ø7/8
[22.2]
[22.2]
ACCESSORY (2)
ACCESSORY (2)
AIR FLOW
AIR FLOW
AIR FLOW
AIR FLOW
BOTTOM RETURN
BOTTOM RETURN
WIDTH
WIDTH
AIR FLOW
AIR FLOW
KNOCK OUTS FOR
KNOCK OUTS FOR
VENTING(5
VENTING(5
PLACES)
PLACES)
A10270
NOTES:
1. Two additional 7/8 ---in. (22 mm) diameter holes are located in the top plate.
2. Minimum return --- air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.
a. For 800 CFM---16 ---in. (406 mm) round or 14 1/2 x 12 ---in. (368 x 305 mm) rectangle.
b. For 1200 CFM---20---in. (508 mm) round or 14 1/2 x 19 1/2---in. (368 x 495 mm) rectangle.
c. For 1600 CFM---22---in. (559 mm) round or 14 1/2 x 22 1/16---in. (368 x 560mm) r ectangle.
d. For airfl ow requ irements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. T he use of both sideinlets,
a combination of 1 side and the bottom, or the bottom only will ensure a dequate return air openings for airflow requirements above 1800 CFM.
FURNACE
SIZE
A
CABINET
WIDTH
IN (mm)
B
OUTLET
WIDTH
IN (mm)
C
TOP AND
BOTTOM FLUE
COLLAR
IN (mm)
D
BOTTOM
INLET WIDTH
IN (mm)
VENT
CONNECTION
SIZE
IN (mm)
SHIP WT
LB (KG)
ACCESSORY
MEDIA
CABINET SIZE
IN (mm)
045---08 14--- 3/16 (360) 12--- 9/16 (319) 9--- 5/16 (237) 12---11/16 (322) 4 (102) 104 (47) 16 (406)
045---12 14--- 3/16 (360) 12--- 9/16 (319) 9--- 5/16 (237) 12---11/16 (322) 4 (102) 107 (49) 16 (406)
070---08 14--- 3/16 (360) 12--- 9/16 (319) 9--- 5/16 (237) 12---11/16 (322) 4 (102) 111 (50) 16 (406)
070---12 14--- 3/16 (360) 12--- 9/16 (319) 9--- 5/16 (237) 12---11/16 (322) 4 (102) 115 (52) 16 (406)
070---16 17--- 1/2 (445) 15---7/8 (403) 11---9/16 (294) 16---1/8 (410) 4 (102) 126 (57) 16 (406)
090---14 17--- 1/2 (445) 15---7/8 (403) 11---9/16 (294) 16---1/8 (410) 4 (102) 127 (58) 16 (406)
090---16 21 (533) 19---3/8 (492) 13 --- 5/16 (338) 19--- 1/2 (495) 4 (102) 140 (64) 20 (508)
090---20 21 (533) 19---3/8 (492) 13 --- 5/16 (338) 19--- 1/2 (495) 4 (102) 146 (66) 20 (508)
110---12 17--- 1/2 (445) 15---7/8 (403) 11---9/16 (294) 16---1/8 (410) 4 (102) 135 (61) 16 (406)
110---16 21 (533) 19---3/8 (492) 13 --- 5/16 (338) 19--- 1/2 (495) 4 (102) 146 (66) 20 (508)
110---22 21 (533) 19---3/8 (492) 13 --- 5/16 (338) 19--- 1/2 (495) 4 (102) 152 (69) 20 (508)
135---16 21 (533) 19---3/8 (492) 13 --- 5/16 (338) 19--- 1/2 (495) 4 (102)* 149 (68) 20 (508)
135---22 24--- 1/2 (622) 22---7/8 (581) 15---1/16 (383) 23 (584) 4 (102))* 163 (74) 24 (610)
155---20 24--- 1/2 (622) 22---7/8 (581) 15---1/16 (383) 23 (584) 4 (102)* 170 (77) 24 (610)
*135 and 155 size furna ces require a 5 or 6--- in. (127 or 152 mm) vent. Use a vent adapter between fu rnace and vent stack. See Installation Instructions for
complete installation requirements.
58CTA/CTX