Table
2
Gas
Rate
(Cu
Ft
Per
Hr)
SECONDS
SIZE
OF
SECONDS
SIZE
OF
FOR
ONE
TEST
DIAL
FOR
ONE
TEST
DIAL
REVOLU-
1
2
5
REVOLU-
1
2
5
TION
cu
ft
cu
ft
cu
ft
TION
cuft
cu
ft
cu
ft
10
360
720
1800
50
72
144
360
11
327
655
1636
51
71
141
355
12
300
600
1500
52
69
138
346
13
277
555
1385
53
68
136
340
14
257
514
1286
54
67
133
333
15
240
480
1200
55
65
131
327
16
225
450
1125
56
64
129
321
17
212
424
1059
57
63
126
316
18
200
400
1000
58
62
124
310
19
189
379
947
59
61
122
305
20
180
360
900
60
60
120
300
21
171
343
857
62
58
116
290
22
164
327
818
64
56
112
281
23
157
313
783
66
54
109
273
24
150
300
750
68
53
106
265
25
144
288
720
70
51
103
257
26
138
277
692
72
50
100
250
27
133
267
667
74
48
97
243
28
129
257
643
76
47
95
237
29
124
248
621
78
46
92
231
30
120
240
600
80
45
80
225
31
116
232
581
82
44
78
220
32
113
225
563
84
43
76
214
33
109
218
545
86
42
75
209
34
106
212
529
88
41
74
205
35
103
206
514
90
40
80
200
36
100
200
500
92
39
78
196
37
97
195
486
94
38
75
192
38
95
189
474
96
38
75
188
39
92
185
462
98
37
74
184
40
90
180
450
100
36
72
180
41
88
176
439
102
35
71
178
42
86
172
429
104
35
69
173
43
84
167
419
106
34
68
170
44
82
164
409
108
33
67
167
45
80
160
400
110
33
65
164
46
78
157
391
112
32
64
161
47
76
153
383
116
31
62
155
48
75
150
375
120
30
60
150
49
73
147
367
f.
To
adjust
input
rate,
remove
cap
that
conceals
regu¬
lator
adjustment.
Turn
adjusting
screw
counterclock¬
wise
(out)
to
decrease
input
When
adjusting,
DO
NOT
change
manifold
pressure
more
than
0.3
in.
wg.
Make
any
major
adjustment
by
changing
main
burner
orifices.
HIGH
ALTITUDE
Ratings
are
approved
for
altitudes
to
2000
ft
for
all
gases.
Ratings
for
altitudes
over
2000
ft
are
4%
less
for
each
1000
ft
above
sea
level.
(Furnace
must
be
derated
by
changing
main
burner
orifices.)
BURNER
AND
PILOT
FLAMES
The
main
burner
flame
should
be
clear
blue,
almost
transparent.
The
pilot
flame
should
be
well
defined.
See
Fig.
6.
Temperature
Rise
Do
not
exceed
the
range
of
temperature
rise
specified
on
the
unit
rating
plate.
Deter¬
mine
the
air
temperature
rise
as
follows:
1.
Place
duct
thermometers
in
return
and
supply
ducts
as
near
furnace
as
possible.
Be
sure
thermometers
do
not
“see"
heat
element
so
that
radiant
heat
will
not
affect
thermometer
readings.
This
is
particularly
important
with
straight-run
ducts.
2.
When
thermometer
readings
stabilize,
subtract
return-
air
temperature
from
supply-air
temperature
to
deter¬
mine
air
temperature
rise.
3.
Adjust
air
temperature
rise
by
adjusting
blower
speed.
Increase
blower
speed
to
reduce
temperature
rise.
Decrease
blower
speed
to
increase
temperature
rise.
Thermostat
Heat
Anticipator
Check
Thermo¬
stat
heat
anticipator
must
be
set
to
match
amp
draw
of
gas
valve
and
electrical
components
in
R-W
circuit.
Accurate
amp
draw
readings
can
be
obtained
at
thermo¬
stat
subbase
terminals
R
&
W.
Figure
7
illustrates
an
easy
method
of
obtaining
actual
amp
draw.
Amp
reading
should
be
taken
after
blower
motor
has
started.
Fig.
7
Amp
Draw
Check
with
Ammeter
Limit
Control
Safety
Check
This
control
shuts
off
the
combustion
control
system
and
energizes
the
circulating-air
blower
motor
if
the
furnace
overheats.
The
recommended
method
of
checking
the
limit
con¬
trol
is
to
gradually
block
off
the
return
air
after
the
furnace
has
been
operating
for
at
least
5
minutes.
As
soon
as
the
limit
has
proven
safe,
the
return
air
opening
should
be
unblocked
to
permit
normal
air
circulation.
By
using
this
method
to
check
the
limit
control,
it
can
be
established
that
the
limit
is
functioning
properly
and
will
“fail-safe”
if
there
is
a
motor
failure.
The
downflow/
horizontal
furnaces
have
a
manual
reset
limit
switch
located
on
blower
housing.
Flow-Sensing
Switch
Safety
Check
This
con¬
trol
proves
operation
of
the
draft
inducer
blower.
Check
as
follows:
1.
Turn
off
115-volt
power
to
furnace.
2.
Remove
control
door
and
disconnect
inducer
motor
lead
wires
from
inducer
printed-circuit
board.
3.
Turn
on
115-volt
power
to
furnace.
4.
Close
thermostat
switch
as
if
making
a
normal
furnace
start.
The
pilot
should
light
and
then
cycle
off
and
on.
If
main
burners
do
not
light,
flow-sensing
switch
is
functioning
properly.
5.
Turn
off
115-volt
power
to
furnace.
6.
Reconnect
inducer
motor
wires,
replace
control
door,
turn
on
115-volt
power.
Draft
Safeguard
Switch
Safety
Check
This
control
permits
safe
shutdown
of
furnace
during
certain
blocked
flue
conditions.
Check
as
follows:
1.
Disconnect
power
to
furnace
and
remove
vent
pipe
from
furnace
outlet
collar.
Allow
time
for
vent
pipe
to
cool
before
removing.
2.
Set
room
thermostat
above
room
temperature
and
restore
power
to
furnace.
3.
After
normal
start-up,
allow
furnace
to
operate
2
minutes.
Block
(100%)
flue
outlet.
Furnace
should
cycle
off
within
2
minutes.
4.
Reconnect
vent
pipe
to
furnace
outlet
collar.
5.
Wait
5
minutes.
Reset
draft
safeguard
switch.
6

Other manuals for Carrier 58DH