Dimensions
58DLA/DLX
UNIT SIZE
A
(CABINET
WIDTH)
D
(SUPPLY
WIDTH)
E
(BOTTOM
RETURN WIDTH)
F
(TOP VENT
OUTLET)
VENT
CONNECTION
SIZE
(see notes 1 & 2)
APPROXIMATE
SHIPPING
WT (LB)
045-08
14-3/16 12-9/16 12-11/16 9-5/16 4 104
045-12
14-3/16 12-9/16 12-11/16 9-5/16 4 107
070-08
14-3/16 12-9/16 12-11/16 9-5/16 4 111
070-12
14-3/16 12-9/16 12-11/16 9-5/16 4 115
070-16
17-1/2 15-7/8 16-1/8 11-9/16 4 126
090-14
17-1/2 15-7/8 16-1/8 11-9/16 4 127
090-16 21 19-3/8 19-1/2 13-5/16 4 140
090-20 21 19-3/8 19-1/2 13-5/16 4 146
110-12 17-1/2 15-7/8 16-1/8 11-9/16 4 135
110-16 21 19-3/8 19-1/2 13-51/6 4 146
110-22 21 19-3/8 19-1/2 13-5/16 4 152
135-16 21 19-3/8 19-1/2 13-5/16 4 (note 1) 149
135-22 24-1/2 22-7/8 23 15-1/16 4 (note 1) 163
155-20 24-1/2 22-7/8 23 15-1/16 4 (note 1) 170
1) 135 and 155 size furnaces require five-
inch vents. Use a 4-5 inch vent adapter be-
tween furnace and vent stack.
2) See Installation Instructions for complete
installation requirements.
28-7/8"
25-1/4"
22-9/16"
JUNCTION BOX
LOCATION
7/8" DIA
ACCESSORY
1/2" DIA THERMOSTAT
WIRE ENTRY
3-15/16"
LEFT HAND GAS
ENTRY
33-5/16"
24-7/8"
5-1/2"
7/8" DIA. ACCESSORY
11/16"
21-5/8"
BOTTOM INLET
1-11/16"
13/16"
11/16"
1-9/16"
2-9/16"
4-13/16"
AIRFLOW
19"
OUTLET
13/16"
11/16"
8-7/16"
1-7/16"
ALTERNATE
JUNCTION BOX
LOCATION (TYP)
VENT OUTLET
5 PLACES (TYP)
3-3/4"
1-1/2" DIA.
RIGHT HAND
GAS ENTRY
1/2" DIA. THERMOSTAT
WIRE ENTRY
SIDE INLET
14-7/8"
7/8" DIA. ACCESSORY
1-1/4"
1"
22-1/16"
A
D
F
E
26-1/8"
(VENT CONNECTION)
24"
(CASING)
NOTES: 1. Two additional 7/8-in. dia. knockouts are located in the top plate.
2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s
recommendations for equivalent diameters.
3. Minimum return-air opening at furnace.
a. For 800 CFM-16-in. round or 14-1/2 x 12-in. rectangle.
b. For 1200 CFM-20-in. round or 14-1/2 x 19-1/3 in. rectangle.
c. For 1600 CFM-22-in. round or 14-1/2 x 22-1/16-in. rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of
single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom of single side
inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate
return air openings for airflow requirements above 1800 CFM.