STARTING AND SHUTTING DOWN
YOUR FURNACE
Should the gas supply fail to shut off or if over heating occurs,
shut off gas valve to the furnace before shutting of the elec-
trical supply. Instead of a continuously burning pilot ame
which wastes valuable energy, your furnace uses an automat-
ic, hot surface ignition system to light the burners each time
the thermostat starts your furnace.
Follow these important
safeguards:
Never attempt to light the burners manually with a match
or other source of ame.
Read and follow the operating instructions on the inside
of main furnace door, especially the item that reads as
follows:
Wait 5 minutes to clear out any gas. Then smell for gas,
including near the oor. If you smell gas,
STOP!
Follow B’’
in the safety information above on this furnace label. If you
dont smell gas, go to the next step.
If a suspected malfunction occurs with your gas control
system, such as the burners not lighting when they should,
refer to the shutdown procedures on the inside of main fur-
nace door, or in the Shutting Down Your Furnace section
and call your dealer as soon as possible.
Check Air Filter:
Before attempting to start your furnace,
be sure the furnace air lter is clean and in place. See Per-
forming Routine Maintenance section in this manual. Then
proceed as follows:
STEPS FOR STARTING YOUR FURNACE
1. Set your room thermostat to the lowest temperature set-
ting. (See Fig. 6.)
2. Close the external manual gas valve. (See Fig. 7.)
6
78
3. Turn OFF electrical supply to the furnace. (See Fig. 8.)
4. Remove main furnace door. (See Fig. 9.)
9
5. The gas valve will have a control switch to turn off and on.
Turn the control switch on the gas control to the OFF
position and wait 5 minutes. (See Fig. 10.) Then smell for
gas, including near the oor. If you smell gas,
STOP!
Fol-
low operating instructions on main furnace door.
6. After waiting 5 minutes, turn the control switch on the gas
control to the ON position. (See Fig. 11.)
7. Replace main furnace door. (See Fig. 12.)
10
WARNING
If overheating occurs or the gas valve fails to shut
off the gas supply, turn off the manual gas valve to
the furnace BEFORE turning off the electrical sup-
ply. (See Fig. 7.) Failure to follow this warning
could result in a fire or explosion, and personal in-
jury/death or property damage.