PLUG
CAP
COLLECTOR
DRAIN TUBE (BLUE
& WHITE STRIPED)
COLLECTOR
TUBE (PINK)
COLLECTOR BOX --_
TUBE (GREEN)
(MOLDED) DRAIN
TUBE (BEHIND
COLLECTOR BOX
DRAIN TUBE)
DRAIN TUBE (BLUE)
FACTORY-SUPPLIED
DRAIN TUBE
COUPLING (LEFT
DRAIN OPTION)
FIELD-INSTALLED
FACTORY-SUPPLiED
DRAIN TUBE
FIELD-INSTALLED
FACTORY-SUPPLIED
V_-IN. CPVC STREET
ELBOWS (2) FOR
LEFT DRAIN OPTION
FIELD-INSTALLED
FACTORY-SUPPLIED
DRAIN TUBE
COUPLING (RIGHT
DRAIN OPTION)
A94163
Fig. 6--Factory-SNpped Upflow Tube Configuration
(Shown With Blower Access Panel Removed}
b. Remove and discard casing drain hole plug button from
desired side.
c Install &ain tube coupling grommet (factor-supplied in
loose parts bag) in selected casing hole.
& Slide drain robe coupling di_ctok_'°supplied in loose parts
bag) through grommet ensuring tong end of coupling fi_ces
blower.
e. Cement 2 factory°supplied 1i2qn. stleet CPVC elbows to
the rigid drain tube connection on the condensate trap. (See
Fig. 6.) These elbows must be cemented together and
cemented to condensate trap drain connection.
NOTE: Failure to use CPV( elbows may allow &ain to kink and
prevent draining.
t_ Connect larger diameter drain tube and clamp (factory°
supplied in loose parts bag) to condensate trap and clamp
securely.
g. Route robe to coupling and cut to appropriate length.
h. Attach robe to coupling and clamp securely.
(ONDENSATE TRAP LOCATION (ALTERNATE UPFLOW
ORIENTATION)
An alternate location fbr the condensate tlap is the left-hand side
of casing. (See Fig 2 and 7)
PLUG
CAP
COLLECTOR BOX
DRAIN TUBE (BLUE
& WHITE STRIPED)
COLLECTOR BOX
TUBE (PINK)
COLLECTOR BOX
TUBE (GREEN)
COLLECTOR BOX
DRAIN TUBE (BLUE)
TRAP
HOUSING
DRAIN TUBE
(VIOLET)
O O
A94164
Fig. 7--Alternate Upflow Tube Configuration and
Trap Location
--9
NOTE: If the alternate tef_-hand side of casing location is used_
the factory-connected drain and relief port robes must he discon-
nected and modified for attachment See Condensate Trap Tubing
(Alternate Upflow Orientation) section for tubing attachment
To relocate condensate trap to the te_t-hand side, perfbrm the
following:
1 Remove 3 tubes connected to condensate t_ap.
2 Remove trap from blower shelf by gently pushing tabs inward
and rotating trap.
3. Install casing hole filler cap (_i_ctory=supplied in loose parts
bag) into blower shelf hole where trap was removed.
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning eoutd result in personal inju W
or death,
Casing hole filler cap must be installed in blower shelf hole
when condensate trap is relocated.
4 Install condensate trap into left=hand side casing hole by
inserting tube cormection stubs through casing hole and
rotating until tabs snap into locking position.
5. Fill unused condensate tlap casing holes with plastic filler
caps (bactory=supplied in loose parts bag).