4
Carrier accessories
*
 
*
 
Factory-authorized and field-installed. Gas conversion kits are A.G.A. recognized.
† Required for installation on combustible floors when no coil box is used, or when any coil box other than a Carrier CD5, CK5, or KCAKC cased 
coil is used.
‡ An external filter is required for right-side return-air installations.
 
**
 
High-pressure switch must be used when operating a dual fuel system. Outdoor Temperature Sensor is packaged with the Thermidistat Control 
and dual fuel thermostat to gain the full benefit and features.
 
UNIT SIZE 040-14 060-14 080-14 080-20 100-20 120-20
GAS CONVERSION KIT — NATURAL-TO-PROPANE
 
*
 
KGANP25012SP
 
GAS CONVERSION KIT — PROPANE-TO-NATURAL
 
*
 
KGAPN20012SP 
 
DOWNFLOW BASE (For Combustible Floors)†
 
KGASB0201ALL
 
VENT TERMINATION KIT (Bracket Only for 2 Pipes)
 
2-in. — KGAVT0101BRA 3-in. — KGAVT0201BRA 
 
CONCENTRIC TERMINATION KIT (Single Exit)
 
2-in. — KGAVT0501CVT 3-in. — KGAVT0601CVT 
 
CONDENSATE FREEZE PROTECTION KIT
 
KGAHT0101CFP
 
SIDE FILTER RACK (Without Filter) Upflow Only‡
 
KGAFR0206ALL
 
ADVANCED PRODUCT MONITOR
 
KGAFP0101APM
 
ELECTRONIC AIR CLEANER (EAC)‡
 
Model AIRA
 
MECHANICAL AIR CLEANER
 
Model 31MF or MACA
 
HUMIDIFIER
 
Model HUM
 
HEAT RECOVERY VENTILATOR
 
Model VA3B, VB5B, or VC5B
 
ENERGY RECOVERY VENTILATOR
 
Model VL3A
 
THERMOSTAT — NON-PROGRAMMABLE 
(Furnace Staging Determined by Furnace Control)
 
For Use with 1-Speed Air Conditioner — TSTATCCNAC01-B
For Use with 2-Speed Air Conditioner — TSTATCCN2S01-B
For Use with 2-Speed Heat Pump — TSTATCCN2S01-B
 
THERMOSTAT — PROGRAMMABLE
(Furnace Staging Determined by Furnace Control)
 
For Use with 1-Speed Air Conditioner — TSTATCCPAC01-B
For Use with 2-Speed Air Conditioner — TSTATCCP2S01-B
For Use with 1-Speed Heat Pump — TSTATCCPDF01-B
For Use with 2-Speed Heat Pump — TSTATCCP2S01-B or TSTATCCPDF01-B
 
THERMOSTAT — NON-PROGRAMMABLE
(Furnace Staging Determined by Thermostat)
 
For Use with 1-Speed Air Conditioner — TSTATCCNHP01-B
For Use with 2-Speed Air Conditioner — TSTATCCN2S01-B
For Use with 2-Speed Heat Pump — TSTATCCN2S01-B
 
THERMOSTAT — PROGRAMMABLE
(Furnace Staging Determined by Thermostat)
 
For Use with 1-Speed Air Conditioner — TSTATCCPHP01-B
For Use with 2-Speed Air Conditioner — TSTATCCP2S01-B
For Use with 1-Speed Heat Pump — TSTATCCPDF01-B
For Use with 2-Speed Heat Pump — TSTATCCP2S01-B or TSTATCCPDF01-B 
 
THERMIDISTAT**
 
TSTATCCPRH01-B
 
ZONING — 2 ZONE
 
ZONEKIT2ZCAR, ZONECC2KIT01
 
ZONING — 4 ZONE
 
ZONECC4KIT01
 
ZONING — 8 ZONE
 
ZONECC8KIT01
Model number nomenclature
 
58MVP 040
Deluxe 4-Way Multipoise 
Variable-Capacity Direct-Vent
Condensing Gas Furnace
Input Capacity (Low/High)
 
040 — 26,000/40,000 Btuh
060 — 39,000/60,000 Btuh
080 — 52,000/80,000 Btuh
100 — 65,000/100,000 Btuh
120 — 78,000/120,000 Btuh
 
130 14
Cooling Size Airflow
 
(400 CFM per 12,000 Btuh)
14 — 1400 CFM
20 — 2000 CFM
 
Series