4.9.5 - INPUTS menu
   
ONOFF_SW Open/Close - Remote start/stop contact
SETP_SW Open/Close - Remote setpoint contact
LIM_SW1 Open/Close - Remote capacity limitation contact
FLOW_SW Open/Close - Water ow rate/customer safety loop contact
leak_v nn.n Volt Leak detector value
Lock_sw2 Open/Close - Customer safety loop contact
4.9.6 - OUTPUTS menu
   
CP_A1 On/O - Compressor output A1
CP_A2 On/O - Compressor output A2
FAN_A1 0 to 2 - Fan speed A1
FAN_A2 0 to 2 - Fan speed A2
EXV_A nnn % Main EXV position
EXV_ECO nnn % EXV Eco position
EV_VALV1 On/O - Shut-o valve compressor A1/EXV Eco
EV_VALV2 On/O - Shut-o valve compressor A2/EXV Eco
RV_A On/O - Four-way valves
EXC_HEAT On/O - Heat exchanger heater
BOILER On/O - Boiler command
EHS_STEP n - Electric heater stage
PUMP_1 On/O - Output pump 1
ALARM On/O - Alarm relay
RUNNING On/O - Unit on relay
4.9.7 - RUNTIME menu
   
HR_MACH nnnnn hours Number of unit operating hours
st_mach nnnnn - Number of unit start-ups
HR_CP_A1 nnnnn hours Number of operating hours compressor A1
st_cp_a1 nnnnn - Number of start-ups compressor A1
HR_CP_A2 nnnnn hours Number of operating hours compressor A2
st_cp_a2 nnnnn - Number of start-ups compressor A2
hr_fana1l nnnnn hours Number of low-speed operating hours fan A1
hr_fana1h nnnnn hours Number of high-speed operating hours fan A1
hr_fana2l nnnnn hours Number of low-speed operating hours fan A2
hr_fana2h nnnnn hours Number of high-speed operating hours fan A2
hr_pump nnnnn hours Number of pump operating hours
4.9.8 - MODES menu
   
m_limit Yes/No - Capacity limitation active
m_ramp Yes/No - Ramp loading active
m_cooler Yes/No - Heat exchanger heater active
m_SM Yes/No - Aquasmart active
m_leadla Yes/No - Master/slave active
m_night Yes/No - Low-noise level night mode active
m_heater Yes/No - Electric heater stages active
m_boiler Yes/No - Boiler active
m_defr_a Yes/No - Defrost active
m_sst_a Yes/No - Low suction temperature
m_dgt_a Yes/No - High discharge gas temperature
m_hp_a Yes/No - High pressure
m_sh_a Yes/No - High pressure
4.9.9 - ALARMS menu
 
ALARMRST Alarm reset
CUR_ALRM Current alarms
ALMHIST1 Alarm history
4.9.10 - CONFIG menu
 
GEN_CONF General conguration menu
PUMPCONF Pump conguration menu
HC_CONFIG Heating mode conguration menu
RESETCFG Reset conguration menu
USERCONFIG User conguration menu
SCHEDULE Time schedule
HOLIDAY Holiday calendar
BRODCAST Summer time/winter time control
DATETIME Time adjustment
DISPLAY Parameter display
CTRL_ID Control identication