Air-Cooled Liquid Chillers
Nominal cooling capacity 163-760 kW
50 Hz
Installation, operation and maintenance instructions


Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Carrier AquaSnap 30RB 602 and is the answer not in the manual?

Carrier AquaSnap 30RB 602 Specifications

General IconGeneral
BrandCarrier
ModelAquaSnap 30RB 602
CategoryChiller
LanguageEnglish

Summary

Introduction

Repair Safety Considerations

Follow regulations, use proper tools, handle refrigerant safely, use approved parts.

Installation Safety Considerations

Check for damage, follow lifting instructions, and ensure proper positioning.

Maintenance Safety Considerations

Authorised personnel, protective equipment, electrical safety, refrigerant handling.

Moving and Siting the Unit

Checks Before System Start-up

Verify installation drawings, diagrams, documents, and safety routes.

Siting the Unit

Install in accessible, safe location, check site loading and levelness.

Dimensions, Clearances

Physical Data - 30RB

Electrical Data - 30RB

162-262 "B" Standard and 30RB 302-802 Units

Provides nominal power, current, voltage, and power input data for various models.

Compressor Usage and Electrical Data

Provides nominal current, maximum current, LRA, and cosine phi for compressors.

Short-Circuit Stability Current

Details short-circuit stability current values for different unit configurations and fuse types.

Application Data

Unit Operating Range

Specifies evaporator and condenser operating limits for different unit models and options.

Minimum Chilled Water Flow (Units without Hydronic Module)

Provides minimum chilled water flow rates for units without hydronic modules.

Pressure Drop Curves for Evaporator and Standard Piping

Graphs showing pressure drop versus water flow rate for evaporators and piping.

Maximum Chilled Water Flow (Units without Hydronic Module)

Provides maximum chilled water flow rates for units without hydronic modules.

Evaporator Flow Rate

Provides minimum and maximum evaporator flow rates for different unit models.

Electrical Connection

Power Supply

Specifies power supply requirements based on the chiller nameplate and electrical data.

Voltage Phase Imbalance (%)

Explains how to calculate and check voltage phase imbalance.

Power Connection/Disconnect Switch

Details options for power connection and disconnect switches.

Field Control Wiring

Refers to wiring diagrams for field control wiring features.

Recommended Wire Sections

Provides guidance on wire sizing for electrical connections based on unit size.

Water Connections

Operating Precautions and Recommendations

Covers precautions for water supply analysis, filtering, treatment, and system components.

Nominal System Water Flow Control

Water Flow Control Procedure

Step-by-step guide for adjusting the control valve to achieve the nominal system flow rate.

Major System Components

High-Pressure Safety Switch

Describes the high-pressure safety switches with automatic reset.

Options and Accessories

Frost Protection

Explains evaporator frost protection based on antifreeze concentration.

Standard Maintenance

Tightening Torques for Main Electrical Connections

Lists torque values for main electrical connections.

Start-Up Checklist for 30RB Liquid Chillers (Use for Job File)

Unit Start-Up

Steps for starting the chiller after all checks are complete.

Check Pressure Drop Across the Evaporator

Guides checking evaporator pressure drop and plotting it on a curve.

Check Voltage Imbalance

Instructions for checking and recording voltage imbalance.

Check Evaporator Water Loop

Details checks for water loop volume, inhibitor, freeze protection, and piping.