EasyManua.ls Logo

Carrier 80AWX Series - Power Wiring Diagram

Carrier 80AWX Series
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
80AWX- 80AWH
English
Installation
Power wiring diagram
Please refer to the Safety Information manual and to the
electrical scheme supplied with the unit.
Electrical installation must be according to g. 15.
Description
80AW-065 80AW-115
M0 M3 M6 T6 M0 M3 M6 T6 T9
A
Power supply
outdoor unit,
backup heater,
booster heater
1pH - 230V 3ph - 400V 1pH - 230V 3ph - 400V
B
Main breaker (eld
supplied)
2 poles 4 poles 2 poles 4 poles
C
Outdoor unit
breaker (eld
supplied)
2 poles, 16 A 2 poles, 25 A
D
Booster heater
breaker (eld
supplied)*
2 poles, 16 A 2 poles, 16 A
Description
Cable
Type
80AW-065 80AW-115
M0 M3 M6 T6 M0 M3 M6 T6 T9
1
Outdoor unit
power supply cable
H07 RN-F 3G x 2.5mm
2
3G x 4mm
2
2
Indoor unit
power supply and
communication
cable
H07 RN-F 3G x 1mm
2
3G x 1mm
2
3
Backup heater
power supply cable
H07 RN-F -
3G x
4mm
2
3G x
6mm
2
4G x
6mm
2
-
3G x
4mm
2
3G x
6mm
2
4G x
6mm
2
4G x
10mm
2
4
User interface
cable
FROH2R 4 x 0.75mm
2
4 x 0.75mm
2
5
Booster heater
power supply
cable*
H07 RN-F 3G x 4mm
2
3G x 4mm
2
6
Booster heater
activation cable
FROH2R 2 x 1mm
2
2 x 1mm
2
7
Sanitary hot water
sensor cable
FROH2R 2 x 0.5mm
2
2 x 0.5mm
2
8
Remote outdoor
sensor cable
FROH2R 2 x 0.5mm
2
2 x 0.5mm
2
* valid for domestic hot water tanks listed in paragraph Accessories
If the user interface is installed in zone, install it in a place which is representative of the room temperature. Avoid direct
contact or proximity with heat or cool sources.
Correct height installation is 1.5 m from the ground.
See electrical scheme.