2. Press down button until LCD readout reads 10˚F below room
temperature. Cooling system should begin to operate within 5
minutes.
Step 7—Checklist
1. Run equipment through several heating and cooling cycles to
ensure proper operation.
2. If equipment is to be left in operation, BOTH heating and
cooling desired temperature settings as well as operating mode
must be properly selected. Refer to Homeowner’s Guide for
procedure.
3. Put away tools and instruments, and clean up debris.
4. Review Homeowner’s Guide with owner.
5. Leave literature packet with owner.
→Fig. 2—Single-Speed Air Conditioner
with Single-Stage Furnace
A97237
24 VAC HOT
24 VAC COMM
HEAT STAGE 1
COOL STAGE 1
FAN
R
C
G
W/W1
Y/Y2
R
C
C
MODEL AC
THERMOSTAT
SINGLE-STAGE
FURNACE
SINGLE-SPEED
AIR CONDITIONER
G
W
Y
Y
→Fig. 3—Single-Speed Air Conditioner
with 2-Stage or Variable-Speed Furnace
A97238
24 VAC HOT
24 VAC COMM
HEAT STAGE 1
COOL STAGE 1
FAN
R
C
G
W/W1
Y/Y2
R
C
C
MODEL AC
THERMOSTAT
TWO-STAGE OR
VARIABLE-SPEED
FURNACE
SINGLE-SPEED
AIR CONDITIONER
See note 1
G
Y
W/W1
Y
W2
A97239
→Fig. 4—Single-Speed Air Conditioner
with Typical Fan Coil
24 VAC HOT
24 VAC COMM
HEAT STAGE 1
COOL STAGE 1
FAN
R
C
G
W/W1
Y/Y2
R
C
C
Y
MODEL AC
THERMOSTAT
TYPICAL
FAN COIL
SINGLE-SPEED
AIR CONDITIONER
See notes 5 and 10
Y/Y2
G
*
*
W2
Y1
O
L
E
*
*
W3
A97123
→Fig. 5—Single-Speed Air Conditioner
with 2-Stage or Variable-Speed Furnace
24 VAC HOT
24 VAC COMM
HEAT STAGE 1
COOL STAGE 1
FAN
R
C
G
W/W1
Y/Y2
R
C
W2
C
Y
MODEL HP
THERMOSTAT
TWO-STAGE OR
VARIABLE-SPEED
FURNACE
SINGLE-SPEED
AIR CONDITIONER
See notes 2 and 3
W/W1
Y/Y2
G
HEAT STAGE 2
N/A
N/A
OUTDOOR
SENSOR
CONNECTION
Y1
B
S1
S2
O/W2
4