T -309
DataReader
Figure 3- 6 Data Reader
b. DataView
The DataView software for a personal computer is
supplied on a floppy disk. This software allows
interrogation, configuration variable assignment,
screen view of the data, hard copy report generation,
cold treatment probe calibration, cold treatment
initialization and file management. Refer to Data
Retrieval manual 62-02575 for a more detailed
explanation of the DataView interrogation software.
c. Communications Interface Module
The communications interface module i s a slave
module which allows communication with a master
central monitoring station.The modulewill respondto
communication and return information over the main
power line.
With a remote monitoring unit installed, all functions
andselectablefeaturesthatareaccessibleattheunitmay
be performed at the master station. Retrieval of all
DataCORDERreportsmayalsobeperformed. Referto
the master system technical manual for further
information.
d. DataLine
The DataLINE software for a personal computer is
supplied on both floppy disks and CD. This software
allows interrogation, configuration variable
assignment, screen view of the data, hard copy report
generation, cold treatment probe calibration and file
management.RefertoDataRetrievalmanual62-10629
for a more detailed explanation of the DataLINE
interrogation software. The DataLine manual may be
found on the net at www.contaner.carrier.com
3.6.11 USDA Cold Treatment
Sustained cold temperature has been employed as an
effective postharvest method for the control of
Mediterranean and certain other tropical fruit flies.
Exposing infested fruit to temperatures of 2.2 degrees
Celsius (36_F) or below for specific periods results in
the mortality of the various stages of this group of
insects.
In response to the demand to replace fumigation with
this environmentally sound process, Carrier has
integrated Cold Treatment capability into its
microprocessor system. These units have the ability to
maintain supply air temperature within one-quarter
degreeCelsiusofsetpointandrecordminutechangesin
product temperature within the DataCORDER
memory, thus meeting USDA criteria. Information on
USDA is provided in t he following subparagraphs
a. USDA Recording
A special type of recording is used for USDA cold
treatment purposes. Cold treatment recording requires
threeremotetemperatureprobesbeplaced atprescribed
locations in the cargo. Provision is made to connect
these probes to the DataCORDER via receptacles
locatedat therear left-handsideofthe unit.Four orfive
receptacles areprovided. Thefourthree-pin receptacles
are for the probes. The five pin receptacle is the rear
connection for the Interrogator. The probe receptacles
are sized to accept plugs with tricam coupling locking
devices. A label on the back panel of t he unit shows
which receptacle is used for each probe.
Thestandard DataCORDER report displays the supply
and return air temperatures. The cold treatment report
displaysUSDA#1, #2,#3 andthe supply and returnair
temperatures. Cold treatmentrecording isbackedupby
abattery so recording cancontinueif AC poweris lost.
b. USDA/ Message T rip Comment
Aspecialfeatureisincorporated inDataLine/DataView
which allows the user to enter a USDA (or other)
message in the header of a data report. The m aximum
messagelengthis78characters.Onlyonemessagewill
be recorded per day.
3.6.12 USDA Cold T reatment Procedure
The following is a summary of the steps required to
initiate a USDA Cold Treatment.
a. Calibrate the three USDA probes by i ce bathing the
probes and performing the calibration function with
theDataReader, DataView orDataLine. Thiscalibra-
tion procedure determines the probe offsets and
storesthem in thecontrollerforusein generatingthe
cold treatment report. Refer to the Data Retrieval
manual 62-02575 for more details.
b. Pre-coolthecontainertothetreatmenttemperatureor
below.
c..InstalltheDataCORDERmodulebatterypack(ifnot
already installed).
d. Placethethreeprobes. Theprobesareplaced intothe
pulpoftheproduct(atthelocationsdefinedinthefol-
lowing table) as the product is loaded.