10
Controls Models 60 & 62
Draw Switch Assembly
The switch assembly consists of three switches:
S the left hand switch which operates the
syrup solenoid valves
S the center switch which operates the spinner
motor
S the right hand switch which operates the
beater motor
All three switches are controlled by draw arm
movement. The left switch activates when the draw
arm is raised 1/2 to 5/8 of an inch (1.3 to 1.6 cm.). The
center and right switches are activated when the draw
armisraised1/4to3/8ofaninch(.64to.95cm.).
Figure 4.
All 3 draw switches are adjustable.
If the left switch is out of adjustment, the following
symptoms will occur:
S Too much syrup will be present at the top
and at the bottom of the shake. The syrup
solenoid is opening too soon and closing too
late.
S Too little syrup will be present at the top and
at the bottom of the shake. The syrup
solenoid is opening too late and closing too
soon.
If the center switch is out of adjustment, the following
symptoms will occur:
S The spinner motor will run continuously after
the draw valve is lowered.
S Product will be dispensed from the spinner
housing before the spinner starts.
Note: The spinner motor will continue to operate 5
seconds after the draw arm is lowered. This is due to
the 5 second time delay relay.
If the right switch is out of adjustment, the following
symptoms will occur:
S The beater motor runs continuously.
S The beater motor does not run until the draw
valveisraisedmorethan3/8ofaninch(.95
cm.).