3. Put away tools and instruments, and clean up debris.
4. Review Homeowner’s Guide with owner.
5. Leave literature packet with owner.
Table 2—Non-Programmable -C Thermostat Quick Reference
THERMOSTAT OUTPUT
TSTAT Model Outdoor Unit Option 5
24v
Hot
Common Fan
Heat
Stage 1
Heat
Stage 2
Heat
Stage 3
Cool
Stage 1
Cool
Stage 2
Reversing Valve
AC01-C AC N/A R C G W/W1 N/A N/A Y/Y2 N/A N/A
HP01-C HP OFF R C G Y/Y2 W/W1 N/A Y/Y2 N/A O/W2/B
HP01-C AC ON R C G W/W1 O/W2/B N/A Y/Y2 N/A N/A
2S01-C 2-Speed AC ON R C G W/W1 O/W2/B N/A Y1 Y/Y2 N/A
2S01-C 2-Speed HP OFF R C G Y1 Y/Y2 W/W1 Y1 Y/Y2 O/W2/B
Model Numbers: TSTATCCNAC01-C, TSTATCCNHP01-C, TSTATCCN2S01-C
Note: AC = Air Conditioner, HP = Heat Pump, 2S = 2-Speed, N/A = Not Applicable
WIRING DIAGRAM NOTES:
1. Furnace must control its own second-stage heat operation via furnace control algorithm. Refer to indoor equipment Installation Instructions
for proper setup.
2. See Option 5 information to convert HP and 2S thermostats to AC thermostat operation.
3. As an option, lock the furnace into low-heat operation and let O/W2/B control high-heat operation. Refer to indoor equipment Installation
Instructions for proper setup.
4. O/W2/B can control second-stage heat. Refer to indoor equipment Installation Instructions for proper setup.
5. Refer to outdoor equipment Installation Instructions for latent kit requirements (if any).
6. Terminals marked with * may not be present on equipment.
7. O/W2/B energizes reversing valve in cooling or heating. See Option 10.
8. Refer to outdoor equipment Installation Instructions for proper setup.
9. If system is wired per diagram, the ACRDJ (jumper) on furnace control board should be removed to allow thermostat to control outdoor
unit staging.
10. Refer to fan coil Installation Instructions for proper wiring.
11. If batteries are installed, C (common wire) is not required between indoor unit and thermostat.
6