APPENDIX B E CCN TABLES (cont)
CONFIG TABLES (cont)
TABLE NAME RANGE UNITS POINT NAME DEFAULT
SCHEDOVR
SET_PNT
Schedule Number
Accept Global Holidays?
Override Time Limit
Timed Override Hours
Accepting an Override:
SPT Override Enabled ?
T58 Override Enabled ?
Allowed to Broadcast a
Global Sched. Override ?
Occupied Heat Setpoint
Occupied Cool Setpoint
Unoccupied Heat Setpoint
Unoccupied Cool Setpoint
Heat-Cool Setpoint Gap
VAV Occ. Cool On Delta
VAV Occ. Cool Off Delta
Supply Air Setpoint
Supply Air Setpoint Hi
Supply Air Setpoint Lo
Heating Supply Air Setpt
Tempering Purge SASP
0-99
Yes/No
0-4
0-4
Yes/No
Yes/No
Yes/No
55 -80
55-80
40 -80
75-95
2-10
0-25
1-25
45-75
45-75
45-75
90-145
-20-80
hours
hours
dF
dF
dF
dF
deltaF
deltaF
deltaF
dF
dF
dF
dF
dF
SCHEDNUM
HOLIDAYT
OTL
OVR EXT
SPT OVER
T58_OV E R
GLBLOVER
OHSP
OCSP
UHSP
UCSP
HCSP GAP
VAVO CO N
VAVOCOFF
SASP
SASP HI
SASP LO
SASPHEAT
TEMPPURG
0
No
1
0
Yes
Yes
No
68
75
55
90
5
3.5
2
55
55
60
85
50
SERVICE-CONFIG TABLES
TABLE NAME RANGE UNITS POINT NAME DEFAULT
ALLM
-10-245
-10-245
-10-245
-10-245
-40-245
-40-245
-40-245
-40-245
-40-245
-40-245
-40-245
-40-245
0-100
0-100
0-5
0-5
-0.25-0.25
-0.25-0.25
0-5000
0-3
5-120
0-5
0-2
0-5
0.0 - 0.5
0-1O0
0-1O0
0-1O0
0-2
dF
dF
dF
dF
dF
dF
dF
dF
dF
dF
dF
dF
%
%
"H20
"H20
"H20
"H20
"H20
%
%
min
SPLO
SPHO
SPLU
SPHU
SALO
SAHO
SALU
SAHU
RALO
RAHO
RALU
RAHU
RRHL
RRHH
SPL
SPH
BPL
BPH
IAQH
BLDG CFG
BPIDR-ATE
BLDGP PG
BLDGP IG
BLDGP DG
BPSO
BLDGPMIN
BLDGPMAX
BLDGPFSO
PWRM
BPSENS
BP RANGE
BPSP
PES1
PES2
BPSELECT
BPPERIOD
BPZ GAIN
BPHPLVL
BPLPLVL
BP
SPT Io alert limit/occ
SPT hi alert limit/occ
SPT Io alert limit/unocc
SPT hi alert limit/unocc
EDT Io alert limit/occ
EDT hi alert limit/occ
EDT Io alert limit/unocc
EDT hi alert limit/unocc
RAT Io alert limit/occ
RAT hi alert limit/occ
RAT Io alert limit/unocc
RAT hi alert limit/unocc
RARH low alert limit
RARH high alert limit
SP low alert limit
SP high alert limit
BP Io alert limit
BP high alert limit
IAQ high alert limit
Building Press. Config
Bldg.Pres.PID Run Rate
Bldg. Press. Prop. Gain
Bldg.Press.lnteg.Gain
Bldg.Press. Deriv.Gain
BP Setpoint Offset
BP VFD Minimum Speed
BP VFD Maximum Speed
VFD/Act. Fire Speed/Pos.
Power Exhaust Motors
O=None,l=4 Mtr, 2=6 Mtr
Building Pressure Sensor
Bldg Press (+/-) Range
Building Pressure Setp.
Power Exhaust On Setp.1
Power Exhaust On Setp.2
Modulating PE AIg. Slct.
BP PID Evaluation Time
BP Threshold Adjustment
High BP Level
Low BP Level
Enable/Disable
0-1
-0.25 -> 0.25
0-1O0
0-1O0
1-3
0-10
0.1-10
0-1
0-1
60
85
45
100
40
100
40
100
60
90
40
100
0
1O0
0
2
-0.25
0.25
1200
o
lO
0.5
0.5
0.3
o.o5
lO
1oo
lOO
1
Dsable
0.25
0.05
35
75
1
1
1
0.05
0.04
152