EasyManua.ls Logo

Carrier WeatherMaker 48TC Series - Cooling Charging Charts

Carrier WeatherMaker 48TC Series
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
COOLING CHARGING CHARTS
Fig. 23 — Cooling Charging Chart - 15, 17.5 Ton (Circuit A)
Fig. 24 — Cooling Charging Chart - 15, 17.5 Ton (Circuit B)
°
°
F 35 40 45 50 55 60 65 70 75 80 85 90 95 100
C 1.7 4.4 7.2 10.0 12.8 15.6 18.3 21.1 23.9 26.7 29.4 32.2 35.0 37.8
185.0
175.0
165.0
155.0
145.0
135.0
125.0
115.0
105.0
95.0
85.0
75.0
Suction Pressure (psig)
Suction Temperature
50HE501045-C
115F / 46.1C
105F / 40.6C
95F / 35.0C
85F / 29.4C
75F / 23.9C
65F / 18.3C
55F / 12.8C
45F / 7.2C
COOLING CHARGING CHART
15 and 17.5 Ton - Circuit A
°
°
F 35 40 45 50 55 60 65 70 75 80 85 90 95 100
C 1.7 4.4 7.2 10.0 12.8 15.6 18.3 21.1 23.9 26.7 29.4 32.2 35.0 37.8
185.0
175.0
165.0
155.0
145.0
135.0
125.0
115.0
105.0
95.0
85.0
75.0
Suction Pressure (psig)
Suction Temperature
50HE501046-C
115F / 46.1C
105F / 40.6C
95F / 35.0C
85F / 29.4C
75F / 23.9C
65F / 18.3C
55F / 12.8C
45F / 7.2C
COOLING CHARGING CHART
15 and 17.5 Ton - Circuit B