APPENDIX B — CCN TABLES (CONT)
Table L — STATUS DISPLAY TABLES (cont)
TABLE DISPLAY NAME RANGE UNITS POINT NAME WRITE STATUS
ECONOMZR
Economizer Act.Curr.Pos. % ECONOPOS
Economizer 2 Act.Curr.Pos. % ECON2POS
Economizer Act.Cmd.Pos. % ECONOCMD forcible
Economizer Active? ECACTIVE
Economizer Control Point dF ECONCPNT
Outside Air Temperature dF OAT forcible
Evaporator Discharge Tmp dF EDT
Controlling Return Temp dF RETURN_T forcible
Econo Current Min. Pos. % ECMINPOS
Econo Current Min. CFM CFM ECMINCFM
Outside Air CFM CFM OACFM
GENERAL
Occupied? YES/NO OCCUPIED forcible
Static Pressure "H2O SP
Building Pressure "H2O BP
Prognostics BP Enable Disable/Enable PG_BP_EN
Prognostics BP Deadband "H2O PG_BP_DB
Outside Air CFM CFM OACFM
Return Air CFM CFM RACFM
Supply Air CFM CFM SACFM
Outside Air Rel.Humidity % OARH forcible
Return Air Rel.Humidity % RARH forcible
Space Relative Humidity % SPRH forcible
Space Temperature Offset ^F SPTO forcible
Supply Air Setpnt. Reset ^F SASPRSET forcible
Static Pressure Reset SPRESET forcible
IAQ - PPM Return CO2 IAQ forcible
OAQ - PPM Return CO2 OAQ forcible
IAQ Min.Pos.Override % IAQMINOV forcible
GENERIC
20 points dependent upon the configuration of
the “generics” table in the Service-Config
section on page 210
HEATING
HVAC Mode…………..: ascii text strings
Control Mode………..: ascii text strings
Heat Control Type……: ascii text strings
Re-Heat Control Type...: ascii text strings
Heating Mode………..: ascii text strings
Requested Heat Stage HT_STAGE
Ht.Coil Act.Current Pos. % HTCLRPOS
Heating Control Point dF HEATCPNT
Heat Relay 1 HS1
Modulating Heat Capacity % HTMG_CAP
Heat Relay 2 HS2
Relay 3 W1 Gas Valve 2 HS3
Relay 4 W2 Gas Valve 2 HS4
Relay 5 W1 Gas Valve 3 HS5
Relay 6 W2 Gas Valve 3 HS6
Heat Interlock Relay HIR forcible
HMZR
HVAC Mode…………..: ascii text strings
Humidimizer Capacity % HMZRCAPC
Condenser EXV Position % COND_EXV
Bypass EXV Position % BYP_EXV
Humidimzer 3-Way Valve On/Off HUM3WVAL
Cooling Control Point dF COOLCPNT
Evaporator Discharge Tmp dF EDT
Heating Control Point dF HEATCPNT
Leaving Air Temperature dF LAT
MODEDISP
System Mode…………: ascii text strings
HVAC Mode…………..: ascii text strings
Control Mode………..: ascii text strings
Currently Occupied On/Off MODEOCCP
Timed Override in effect On/Off MODETOVR
DCV resetting min pos On/Off MODEADCV
Supply Air Reset On/Off MODESARS
Demand Limit in Effect On/Off MODEDMLT
Temp.Compensated Start On/Off MODETCST
IAQ pre-occ purge active On/Off MODEIQPG
Linkage Active - DAV On/Off MODELINK
Mech.Cooling Locked Out On/Off MODELOCK
HVAC Mode Numerical Form number MODEHVAC