Malfunction display of outdoor unit’s DSP1
5.    MALFUNCTION 
Table.5-1 
5 
Owner's manual
If the problem still exists, please contact the sales distributor or the service center, tell us your model No. and the detail of the error.
1 
2 
3 
11 
12 
13 
14 
15 
16 
19 
20 
E0 
E1 
E2 
xH0 
H1 
H2 
H3 
 xH4 
H5 
H9 
21 
P1 
P2 
17 
18 
P0 
25 
26 
27 
28 
29 
30 
31 
32 
35 
P4 
P5 
xP6 
P9 
xL0 
36 
37 
xP3 
33 
34 
 
No. 
Error code 
Error or protection type 
Note 
Only display in slave unit 
Outdoor unit COMM.Error 
Phase protection 
COMM.Error with indoor unit 
H6 
H7 
38 
39 
40 
41 
H8 
Twenty minutes after the first power on or indoor 
and outdoor communication break off after 2 
minutes when the unit has been running for 20 minutes
COMM. Error between IR341 and main chip 
Only main unit will display 
Qty.of outdoor unit increases error 
Only main unit will display 
unrecoverable module protection outage(P6) 
Three times the P2 protection in 60 minutes
Not recoverable until re-power on 
 
Three times the P4 protection in 100 minutes
Not recoverable until re-power on 
Qty.of indoor units decreases error 
Indoor unit lost for over 3 minutes; not recoverable, 
until the unit qty. recovers
High-pressure sensor error
Air discharging pressure Pc≤0.3MPa
Three times the P9 protection in 60 minutes
Not recoverable until re-power on 
F0 
23 
Three times the PP protection in 150 minutes
Not recoverable until re-power on 
C7 
24 
Three times the PL protection in 100 minutes
Not recoverable until re-power on 
Hc 
22 
Auxiliary unit error(y=1,2, 3.e.g,1Hd stands for auxiliary 
unit1 error)
Y represents a unit which is not No. 0
yHd 
Inverter compressor top Temp.protection 
High-pressure protection
Low-pressure protection
Compressor current protection 
Discharge Temp.Protection 
High condenser Temp.protection 
Inverter module protection 
 
X represents for a system, 1 is A system, 2 is B system; 
reports H4 if P6 protection is activated three times 
60 minutes
DC fan protection
DC compressor module error 
X represents the system, 1 is A system, 2 is B system
xL1 
DC bus low-pressure protection
xL2 
DC bus high-pressure protection
xL3 
Reserve 
MCE error/synchronization/closed loop 
xL4 
Zero-speed protection
xL5 
xL6 
xL7 
xL8 
xL9 
Reserve 
Phase-error protection
Protection of the speed change between a moment 
before and after is 
>15Hz
Protection of the speed change between the setting 
speed and the actual speed 
>15Hz
42 
43 
44 
COMM. Error between 0537 and main chip 
Qty.of outdoor unit decreases error 
 
Reports H5 after P2 protection is activated three times 60 minutes 
Reports H6 after P6 protection is activated three times 100 minutes 
Reports H9 if P9 protection is activated three times in 60 minutes  
PL 
Inverter module Temp.sensor error
Reports C7 if PL protection is activated in 100 minutes.
PP 
Protection at an insufficient degree against superheating 
compressor discharge
Reports F0 if PP protection is activated in 150 minutes
X represents for a system, 1 is A system, 2 is B 
system, not recoverable until re-power on
X represents the system, 1 is A system, 2 is B system
X represents the system, 1 is A system, 2 is B system
X represents the system, 1 is A system, 2 is B system
X represents the system, 1 is A system, 2 is B system
X represents the system, 1 is A system, 2 is B system
X represents the system, 1 is A system, 2 is B system
X represents the system, 1 is A system, 2 is B system
X represents the system, 1 is A system, 2 is B system
X represents the system, 1 is A system, 2 is B system
4 
5 
6 
7 
8 
9 
10 
E3 
E4 
E5 
E7 
E8 
xE9 
E6 
Reserve 
Outdoor temp. sensor error 
Voltage protection
Reserve 
Discharge temp.sensor error 
Outdoor unit address error 
Mismatching the drive model
X represents for a system, 1 is A system, 2 is B system 
X represents for a system, 1 is A system, 2 is B system
Reserve