3
Prepare hoses
A
Position truck carriage behind the attachment.
B Determine hose lengths required.
C Cut hoses to length, install end fittings.
CAUTION: Hoses should be 160 bar working
pressure rated for all attachment functions.
INSTALLATION USING RH & LH 2-PORT
THINLINE
TM
HOSE REELS, SINGLE IHR:
INSTALLATION USING RH 2-PORT HOSE
REEL and LH 4-PORT HOSE REEL:
WARNING: Hose connecting revolving
connection OPEN port to 4-port hose reel
must be connected to outer-most hose on
reel only.
RC3755.eps
RC3756.eps
Release
Release
Clamp
Clamp
Rotate CCW
Rotate
CCW
Rotate CW
Rotate
CW
Swing Left
Swing Left
Swing Right
Swing Right
CAUTION: Rotate function supply circuit back pressure
exceeding 35 bar and a maximum flow rate of 54 L/min.
can result in excessive oil heating, reduced attachment
performance and shortened hydraulic system life.
Check for restrictions such as numerous fittings and
fitting/hose sizes less than No. 8.
4
Flush hydraulic supply hoses
A
Install hoses as shown below.
B Operate auxiliary valves for 30 seconds.
C Remove union fittings.
D Install hoses to revolving connection fittings as
shown in step 3, above.
RC0748.eps