18
PTO
AUTOMATIC STOP/RUN OF PTO
SHAFT WHEN IMPLEMENT IS
LIFTED/LOWERED
1. Turn on pto
2. Switch on auto pto.
3. Drive off and start working.
1
2
ADJUSTMENT OF ON/OFF POINTS
Adjust the shut off and turn on points in accordance to the lifting height of the rear hitch:
1. Press the auto pto switch for more than 3 seconds.
2. Lift or lower the rear hitch to the desired position (here 30% lifting height) where the pto
should stop turning. u = up
3. Press auto pto switch shortly.
4. Lift or lower the rear hitch to the desired position (here 65% lifting height) where the pto
should start turning. d = down
5. Press auto pto switch shortly.
6. Finished. End