CONTROLLER
3 - 35
CX EXCAVATORS
DIAGNOSTIC SYSTEM
DIAG6 – Past Failure Condition on Machine (Hours)
The hours that fault occurred will be displayed in the same window as
the fault code that was detected in DIAG5.
Past fault codes and hours will be cleared if the Work mode switch is
pressed for 10 seconds.
Hours shown in DIAG6 is computer “ON” hours since the last time the
data was cleared. Not machine hour-meter hours.
Note: To erase machine fault codes switch to DIAG5 and press the Work
mode switch for 10 seconds. The warning buzzer will sound. Turn OFF the
key switch to complete the process.
DIAG MODE Hi, H
6 M 0 0 0 0
M 0 0 0 0 M 0 0 0 0
M 0 0 0 0 M 0 0 0 0
M 0 0 0 0 M 0 0 0 0