— 10 —
Check point 1 2 3456789101112
Power ON
23.8(AC) 31.4
25.2 7.61 24 8.2 8.1 0.6 0 5 5.6 5
Power cord off 0 0 0000000000
[PWD signal]
After plugging the AC cord into outlet, VP voltage appears on the base terminal of transistor Q3.
When the VP exceeds 16 volts, Q3 is turned on by the differential voltage between base and
emitter terminal of transistor Q3.
Then the PWD signal goes to GND level and informs "Power ON" to the CPU.
When the VP drops less than 16 volts, Q3 is turned off.
Then the PWD goes high level since the PWD is pulled up to VDD.
When the CPU receives "High" signal of PWD, CPU goes to "Power failure process".
Note:When plugging the AC cord into outlet, all voltages are supplied to the PCB.
If you open the machine for repair, make sure to unplug it.
[Location for voltage check points]
Actual value on the E259-1 PCB [unit : V]
2
3
4
6
5
7
8
9
1
11
10
12