43
System Parameter List
Note 1:
This is the version number of models with the same System Exclusive Model ID = 11-02. This value is used to specify
the model for a parameter send request from an external source.
Note 2:
This is a request to look up and cancel the tone status of parts whose bits are set. It does this by canceling the DSP Line
selection of the parts whose corresponding bit is 1.
20.2 Data Management Command Parameter List
System Exclusive Format
ParamID Parameter ps index bit Value Default Setting Value
(Decimal)
00r
Model Version ID (Note 1)
0000 00 0E 00 0 n0 = reserved
n1 = CTK-691
n2 = WK-3000
n3 = WK-3500
n = version (00 to 3F)
03 DSP Bypass (Note 2) 0000 00 10 0-FFFF 0 Bit0...Part1
Bit1....Part2
:
Bit15...Part16
0...Nop
1...DSP cancel
Field Value
01 SYSEX F0
02 MAN 44
03 MOD 11,02
04 dev Either 00 to 1F, or 7F
05 act 00(IPC), 01(IPR)
06 cat Command = 0
07 prm 00-7F
08 ilen/dlen 0 / bit size - 1
09 ps 0
10 index 0
11 data (See the Parameter List)
12 sum None
13 EOX F7