6.10.2. Cable Specifications
Cable for Chain Connection (short distance)
A cable for the chain connection within distance of 1 meter or less (between DT-960IOE and
DT-960IOE) is available as option. The model number of the cable is DT-788RSC (cable length: 1
m).
View from side
View from above
1 2 3 4 5 6
Max. 1 m
Modular plug
6/6-6 FR SYK
1 2 3 4 5 6
Cable (see Table 10.13)
Fig. 6.5
Table 6.11
Cable
Conductive 20/0.1 A
Insulation Semi-rigid P.V.C
Core wire
Finish form 20/0.1 A
Insulation P.V.C Sheath
Finish O.D. φ4.3 ±0.1 mm
Conductive resistance 0.12 ohm/m or less Characteristics
Insulation resistance 50 Mohm or greater
Wiring of the cable (cross cable)
Cradle at downstream side Cradle at upper stream side
Pin no. Signal Pin no. Signal
1 1
2 2
3 TRUE 3 INVERT
4 INVERT 4 TRUE
5 5
6
6
Fig. 6.6