ā 9 ā
3-2. Scale buffer circuit
When a measured object is put on the scale, the scale starts weighing. During
weighing, MO signal is "H". When the weighing is finished with indication of the
weight of measures object, the MO signal becomes "L".
Then EN signal is output to the scale and the scale output the weight data
(D0~D3) to the scale buffer.
Pin description of scale connector
Pin No. Signal Name Descriptions
1 NC Non connection
2 NC Non connection
3 NC Non connection
4 NC Non connection
5 NC Non connection
6 NC Non connection
7 D1 Data
8 D2 Data
9 D3 Data
10 ENABLE Enable signal
11 D0 Data
12 CLOCK Clock signal
13 MOTION Motion signal
14 RANGE Out of range signal
15 GND GND
16 GND GND