— 60 —
[Print]
* Error print
| ARCNET RETRY OVER | Selected retry number was exceeded.
| ARCNET BLK ERR | Received does not correspond to the sent Block No.
| ARCNET DATA ERR | Received data does not correspond to the sent data.
| ARCNET LENG ERR | Received data length does not correspond to the sent data length.
| ARCNET TIMEOUT | Time out error when starting the ECR or between blocks.
| ARCNET OPEN ERR | ARCNET initialization failed.
ARCNET rllmmx0a51
END rllmmx0a51
[ 23 ] ARCNET batch test
[Function]
This test will perform the ARCNET counter communication with the fixed set value.
Connect the two ECRs and perform the counter communication test.
The number of retries will be displayed in the upper right corner of the LCD.
[Operation]
* Send ECR
Operation : 1 5 0 SUBTOTAL
Fixed set value
ID of the other ECR: 01, Own ID: 02
Mode selection: send mode
Baud rate: 312 kbps
The number of retries = 5
* Receive ECR
Operation : 250 SUBTOTAL
Fixed set value
ID of the other ECR: 02, Own ID : 01
Mode selection: receive mode
Baud rate: 312 kbps
The number of retries = 5
[LCD]
* Send ECR
* Receive ECR
[Print]
Refer to [ 22 ] ARCNET test for the error print.
ARCNET 150
END 150
ARCNET 250
END 250