Page 5 of 14 EQ2009 R 1.6 1.8 Rev. 02 del 2/05/2011
4.2) DIP-SWITCH S3 FUNCTIONS
Test photocells on FOTO 1 on.
Test photocells on FOTO 1 off.
Test photocells on FOTO 2 on.
Test photocells on FOTO 2 off.
Working type B
(it trains the card for signal clinking LAMP and it changes the work formality of the input Safety edge 1 and 2.).
Working type A (standard).
Survey obstacle (reverser ampherometric) on both motors excluded.
Survey obstacle (reverser ampherometric) on both motors active.
Setting of survey obstacle power in slowing down on both motors for a high range of force
Setting of survey obstacle power in slowing down on both motors for a low range of force
Maximum power to the motors M1 and M2 in closing in the last 2”, ON.
Maximum power in closing in the last 2” ON, only for motor M1( M2 does not work is that the close limit is on that
is off). Default Casit.
After pedestrian opening of M1, close in both M1 M2(if close limit switch of M2 is on, M2 does not work).
After pedestrian opening of M1, closes only M1(M2 does not work whether the close limit switch is on that is
off). Default Casit.
The output light of courtesy is immediately disarmed at the end of closing.
The output light of courtesy is disarmed three minutes later than the end of closing.
During the opening and the closing, it stops the movement and reopens
totally when obstacle removed.
In closing, the gate stop, and then manoeuvre in the opposite way.
In opening it doesn’t works.
In opening and in closing, the gate stop, and then manoeuvre in the
opposite way for 2 sec. but 1 minute later it closes.
In opening, the gate stop, and then manoeuvre in the opposite way for 2
sec. but 1 minute later it closes. In closing it doesn’t works..
4.3) DIP-SWITCH FUNCTIONS S4 SELECTION MOTOR WITH/WITHOUT ENCODER – WITH WITHOUT LIMITSWITCHES
DIP1 - Selection motor with/without encoder.
DIP2-Selection function/connect limit switch.
MOTORS WITH OR WITHOUT LIMITSWITCHES
STANDARD MOTOR WITHOUT ENCODER
The participation of the encoder/reverser inverts the motion
of the gate till the activation of the limitswitch closes.
USE IT WITH MOTORS WITHOUT LIMITSWITCHES
Test triac off. To connect the limit
switches on the motor phases.
During the last 6 sec. of the stroke, the working of
encoder/reverse it stops the gate without reverse.
USE IT WITH MOTORS WITHOUT LIMITSWITCHES
Test triac on. To connect the limit
switches a 20,21,22,23,24 di M9. Default
Casit.
SEE CHAPTER 11 ABOUT OPERATION WITH ENCODER
CONNECTIONS J1 RX = graft for the receiver.
5) DEFAULT TIMES
The control panel foresees some times of work pre setted:
time of work on 2 motors = 50 seconds; time of pedestrian opening = 10 seconds
time - break = 8 seconds; time of pedestrian break = 8 seconds
leaf delay in opening = 3 seconds; leaf delay in closing = 5 seconds
To eliminate the leafs delay (or if you used one motor only) select the time of unified work for both the motors on the motor M1 S1-
dip 5 ON , it’s good for default times only.
6) TIME OF COMPENSATION
To balance the differences of speed between the opening and the closing of the gate during the run, or to balance the different
speeds during an inversion of the run, especially if the last part of the stroke has the speed of deceleration, the control panel has
balance times at the end of time of work in 3 sec. if the slowing is not used and 6 sec. if slowing is working.
7) DEVICES OF PLANNING
The pushes button PS1s (START), PS2 (Pedestrian), PS3 and the leds L14, L15, L16 are used for the formulation of the parameters
in the planning menu (see chapter 8).