1. Remove the water tank. Fill it with a mixture of water and citric acid (5%). Put the
water tank back in.
2. Select the descaling / cleaning function and confirm with . C01 is now
displayed.
3. When int the display flashes and the device beeps, then add fresh water to the
tank. Put the tank back in and confirm with . C02 is now displayed.
4. The limescale residues are flushed into the interior of the device. When the device
displays "END", the process is complete.
5. Wait until the device has cooled down and then clean the inside of the device.
14.2.5 Removal of the door
You can clean the door with a mild detergent and water.
The door can be removed for better cleaning.
To do this, open the door to the maximum (1). Then fold up the safety bar as far as
possible (1a 1b). Hold the door by the handle and lift it out of the guide. (2). You can
now clean the door. Then dry it thoroughly. Insert the door hinges back into the guide
from top to bottom. Then fold the safety bar down again and close the door. Check that
the door is securely mounted.