EasyManua.ls Logo

Cattron CommandPro Series - Receiver Repairs; Replacing the Rf;Relay Board; Changing the Receiver Identity Code; Receiver Specifications

Default Icon
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CommandPro
®
General Purpose & Safety Applications
User Manual
23
9M02-9028-A031-EN
Rev 4
7.4 Receiver Repairs
WARNING
Remove external power to the receiver enclosure before performing electrical work inside the
cabinet.
Refer to Figure 5.
7.4.1 Replacing the RF/Relay Board
1. Switch off power to the receiver and open the enclosure door.
2. Unplug the RF coax connector by pulling straight up and gently twisting back and forth. Remove the
grounding strap. Unplug all of the electrical connectors.
3. Remove the four screws from the corners of the receiver assembly mounting plate and remove the
assembly from the enclosure.
4. Replace in reverse order.
7.4.2 Changing the Receiver Identity Code
1. Using the RAC16A Series Programmer, attach the programming plug to the 6-pin connector on the
receiver circuit board. Verify the ID CODE is displayed.
2. Enter the new Identity Code and press the PRG key.
3. Remove the programming plug.
Note: Refer to the RAC16A Series Programmer User’s Manual for more detailed instructions.
7.5 Receiver Specifications
Item
Detail
Power Requirements
Standard
12-24 VDC (11 VDC to 14 VDC)
Optional
24, 115 or 230 VAC, 1 phase, 50/60Hz
Receiver Type
Dual Conversion FM
Sensitivity
1 µV usable
IF Bandwidth
180 KHz
Antenna
3” tuned element
Decoder
Microprocessor-controlled
Response Time
60 milliseconds
!