Ducting
The ducting used should be 150mm, rigid circular pipe and must be
manufactured from fire retardant material, produced to BS 476 or DIN
4102-B1.
Wherever possible utilise rigid circular pipe which has a smooth
interior, rather than the expanding concertina type ducting. The
lengths of ducting with minimal eect on performance are as follows:
4 metres with 1 x 90° bend.
3 metres with 2 x 90° bends.
2 metres with 3 x 90° bends.
Longer ducting can be used but the performance of the extractor will
likely be reduced.
Please note: Ducting components and ducting kits are optional
accessories and have to be ordered, they are not automatically
supplied with the hood. Use of ducting less than 150mm in diameter
will aect performance and increase the noise produced by the
extractor.
Note that the ducting should be secured and sealed to the vent outlet
pipe / valve using appropriate jubilee clips or securing means.