EasyManua.ls Logo

CDA RC9321

CDA RC9321
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
Table for the choice of the injectors
GB
Cat: II 2H3+
I
NCREASE OF AIR NECESSARY FOR GAS COMBUSTION (2 m
3
/h x kW)
BURNERS Air necessary for combustion [m
3
/h]
Auxiliary (A) 2,00
Semi-rapid (SR) 3,50
Rapid (R) 6,00
Triple-ring 7,00
Oven (left) 7,40
Grill (left) 5,00
Oven (right) 4,40
Grill (right) 4,00
Auxiliary (A) 1,00 0,30
50
-
72 (X)
-
Semi-rapid (SR) 1,75 0,45
65
-
97 (Z)
-
Rapid (R) 3,00 0,75
85
-
115 (Y)
-
Triple-ring 3,50 1,50
95
-
135 (T)
-
Oven (left) 3,70 0,75
92
fully open
140
5
Grill (left) 2,50 -
80
fully open
120
4
Oven (right) 2,20 0,63
72
fully open
110
4
Grill (right) 2,00 -
70
fully open
105
2
Nominal
Power
[kW]
Reduced
Power
[kW]
Ø injector
[1/100 mm]
G 30 - 28-30 mbar
G31- 37 mbar
G 20
20 mbar
BURNERS
Ø injector
[1/100 mm]
Tube ring
opening
[mm]
Tube ring
opening
[mm]

Related product manuals