2EASY 2-wire Touchscreen Video Door
Station
CDV-T5
EN
WARRANTY
YEAR
2
Question and Answer IconNeed help?

Do you have a question about the CDVI 2EASY CDV-T5 and is the answer not in the manual?

Overview

The CDV-T5 is a 2-wire touchscreen video door station designed for security and access control systems. It is part of the 2EASY series, offering a user-friendly interface and robust functionality for residential and commercial applications. The device is typically supplied with 24Vdc power from a CDV-PC7 power combiner unit.

Function Description:

The CDV-T5 serves as the primary interface for visitors at an entrance, allowing them to communicate with residents and gain access. Its core functions include:

  • Video Intercom: Features a 1/2.7" fisheye camera with a 170° wide-angle lens, providing a broad view of the entrance area. It includes Night View LED for clear visibility in low-light conditions.
  • Audio Communication: Equipped with a speaker and microphone for two-way audio communication with residents.
  • Access Control: Supports multiple methods for unlocking the door:
    • Room Number Input: Visitors can dial a room number directly on the touchscreen keypad.
    • Namelist Selection: A namelist feature allows visitors to browse and select a resident's name from a list to initiate a call.
    • Password Entry: Residents can enter a personal unlock password on the touchscreen to open the door.
    • Access Card: Integrated RFID card reader supports 125KHz and 13.56MHz (MIFARE® Classic) cards for quick and convenient access.
  • Status Indication: An LED status indicator provides visual feedback on the device's operational state.
  • Door Station ID Settings: When multiple door stations are installed in a system, DIP switches allow for correct ID configuration (00 for the first, 01 for the second, etc.).
  • Unlock Time Setting: The unlock time can be configured via DIP switch (1 or 5 seconds) or through the door station's settings.
  • Invisible Keys A and B: These touch buttons can be activated via DIP switch for additional functionality.
  • System Integration: Designed for 2-wire (no polarity) bus line connection, typically to a CDV-PC7 power combiner unit and CDV-BDU (Building Distributor Unit) for multi-apartment systems. It supports star topology with CDV-DBC4A distributors for extending the system to multiple slave monitors.

Important Technical Specifications:

  • Power Supply: 24Vdc (supplied by CDV-PC7)
  • Camera: 1/2.7" fisheye, 170° wide angle
  • Power Consumption: Standby: 1W, Working: 5W
  • Card Reader: RFID, 125KHz, 13.56MHz
  • Screen: 5" digital colour TFT, 800x480 pixels
  • Unlock Power Output: 250mA @ 12Vdc
  • Unlocking Time: 1-99 seconds (configurable)
  • Operating Temperature: -10°C to 50°C
  • Wiring: 2-wire (no polarity)
  • IP Protection: IP65 (screen)
  • Dimensions:
    • Surface Mount: 316(H)×133(W)×48(D)mm (3-gang)
    • Flush Mount: 232(H)×133(W)×48(D)mm (2-gang)
  • Warranty: 2 years

Usage Features:

  • Main Menu: The touchscreen displays a main menu with options for Keypad, Namelist, Unlock, and Help, along with date, time, and a setting page access button.
  • Installer Mode: Accessible via a password (default: 66666666), this mode allows for comprehensive system configuration, including:
    • System Settings: Video format (PAL/NTSC), tone prompt, sound volume, unlock mode (normally open/closed), unlock timing, night LED level (auto/always on/always off), and raincover enable (adjusts camera angle if a raincover is used).
    • Other Settings: Default menus select (room number, namelist, classic main menu), display list date and time (enabled/disabled), display unlock (enabled/disabled), and display name only or with room number.
    • Villa Mode: Enables one-touch setup of 1 to 4 named buttons on the display for direct calling in villa environments.
    • Switching Access Card Output (DT-ACC): Allows card data to be extracted from the bus to a standard Wiegand reader port of an ACU (e.g., CDVI's ATRIUM system).
  • Monitor Management: Within installer mode, monitors can be managed, including enabling/disabling, flashing status, and removing/enabling from the namelist. Each monitor has settings for its address, manage password, unlock code, local dial number, and name.
  • Card Management:
    • Add Cards: Allows adding new access cards by selecting a room number, entering a card holder's name, and presenting the card to the reader or manually entering the 10-digit card ID.
    • View Cards: Displays stored card information by searching by room, name, card ID, or date.
    • Delete Cards: Provides options to delete all cards or individual cards from the system.
  • Password Management:
    • Disable Code Unlock: Prevents users from unlocking with a password.
    • Change Public Unlock Password: Allows changing the default public unlock password (default: 1234).
    • Change Installer Password: Allows changing the installer password.
  • Firmware Update: The device supports firmware updates via SD card.

Maintenance Features:

  • Firmware Update Notice: Provides instructions for updating the door station to the latest firmware, emphasizing that card and password information is stored in the touchscreen module and retained after updates.
  • Backup & Restore:
    • Backup to SD: Allows backing up system settings, other settings, namelist (including private passwords), and call records to an SD card.
    • Restore from SD: Enables restoring the system from a previously saved backup.
    • Restore Factory Settings: Resets all settings, cards, namelist, and passwords to their default values.
  • RES Manage: Uploads customised files such as display language, default settings, and logo. It also allows for backing up and restoring these customisations to/from an SD card, or cleaning customisation to revert to the standard version.
  • Device Information: Provides access to information such as firmware version, uptime, and SN number for troubleshooting and record-keeping.
  • DIP Switch Configuration: Physical DIP switches allow for initial setup and modification of key parameters like door station ID and unlock time, requiring a power restart after changes.