Number Problem Num Possible cause Solution
1 The control panel
display shows the
water tank indicator
light
1.1 Water tank is out of
water.
Fill the water tank and insert
it into the appliance.
1.2
It is necessary to
calibrate the water level
sensor.
When the appliance is in
standby mode:
1. Remove the water tank.
2. Remove the sticker from
the reset button on
the water level sensor
located on the corner of
the tank housing. Then,
press and hold the reset
button for 6 seconds.
3. Unplug the appliance.
4. Plug in and switch on
the appliance after 10
seconds. Insert the tank
when you have lled it.
2
The display shows
a square of dashed
lines (Fig. 5), and the
appliance does not
dispense water
2.1 The water tank is not
correctly installed.
Install the tank properly
inside the coee machine.
Push the bottom side all the
way in.
2.2 No water ows through
the pump.
Open the rear panel and
inject water into the water
pump.
2.3 The internal piping is
blocked.
Please contact the ocial
Cecotec Technical Support
Service.
3
The display shows
a square of dashed
lines (Fig. 5), press
the Exit icon and the
water will exit, but
the warning cannot
be removed
3.1 Water ow meter wires
are coming loose
or the water ow meter
is broken.
Please contact the ocial
Cecotec Technical Support
Service.