3
operating the meter.
Always remove the test leads before replacing the battery.
Inspect the condition of the test leads and the meter itself for
any damage before operating the meter. Repair or replace
any damage before use.
Use great care when making measurements if the voltages
are greater than 25VAC rms or 35VDC. These voltages are
considered a shock hazard.
Remove the battery if the meter is to be stored for long
periods.
Always discharge capacitors and remove power from the
device under test before performing Diode, Resistance or
Continuity tests.
Voltage checks on electrical outlets can be difficult and
misleading because of the uncertainty of connection to the
recessed electrical contacts. Other means should be used
to ensure that the terminals are not "live".
If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may
be impaired.
Input Limits
Function
Maximum Input
A AC
1000A
V DC, V AC
600V DC/AC
Resistance, Diode, Continuity,
Capacitance, Frequency, Duty
Cycle, Test
250V DC/AC
Temperature (/)
60V DC/24V AC