RESISTANCE MEASUREMENTS
WARNING: To avoid electric shock, disconnect power to the unit
under test and discharge all capacitors before taking any
resistance measurements. Remove the batteries and unplug the
line cords.
1. Set the function switch to the green
Ω CAP position.
2. Insert the black test lead banana plug into
the negative COM jack.
Insert the red test lead banana plug into the
positive jack.
3. Press the MODE button to indicate “” on
the display.
4. Touch the test probe tips across the circuit
or part under test. It is best to disconnect
one side of the part under test so the rest of
the circuit will not interfere with the
resistance reading.
5. Read the resistance in the display.