Clamp Meter
2
Power Source:
1.5V size AAA battery X 2
Typical battery Life: 50 hours (without buzzer, backlight function)
Auto Power Off:
If there is no key or dial operation for 30 minutes, the meter will power
itself off to save battery consumption. This function can be disabled by
press and hold the “ HOLD” button then power the unit on.
Over Load:
When the signal larger than the maximum will be show
.
Maximum jaw opening:
∅ 25 mm
Dimensions:
210 x 62 x 36 mm
Weight:
273g (with battery)
Accessories:
Carrying case, Batteries, Test Lead & Instruction Manual.
3. ELECTRICAL SPECIFICATION
Accuracy is to within ± [% of the reading + number of counts (dgts)] in
the reference conditions indicated in the appendix.
3-1 Direct Voltage
Range Resolution Accuracy
600 V 0.1 V 1% + 2dgts
Input impedance: 1 MΩ
3-2 Direct Voltage ( Peak Model )
Range Resolution Accuracy
600 V 0.1 V 1.5% + 8dgts
Input impedance: 1 MΩ
3-3 Alternating Voltage
Range Resolution Accuracy
600 V 0.1 V 1.2% + 5dgts
Input impedance: 1 MΩ
3-4 Alternating Voltage ( Peak Model )
Range Resolution Accuracy
600 V 0.1 V 1.7% + 10dgts
Input impedance: 1 MΩ