EasyManua.ls Logo

Center 265 - ELECTRICAL SPECIFICATION; ACmA (True RMS) Measurement

Center 265
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Center 265 True RMS Leakage Current Clamp Meter
3
Power Source:
1.5V size AAA battery X 2
Typical battery Life: (without buzzer, backlight)
40 hours at AC mA and ACA and ACV function;
60 hours at DCV and Ohm function. (Alkaline battery)
Auto Power Off:
If there is no key or dial operation for 30 minutes, the meter will power
itself off to save battery life. This function can be disabled by pressing
and holding the HOLD button and powering on the unit.
Overload Indication:
When the applied signal is larger than the maximum for the range in
use the display will show .
Maximum Jaw Opening:
23 mm
Dimensions:
206 x 76 x 33.5 mm
Weight:
262g (with battery)
Accessories:
Carrying case, Batteries, Test Leads & Instruction Manual.
3. ELECTRICAL SPECIFICATION
The accuracy specification is defined as ± ( percentage of reading +
number of counts ) At 23±5°C, 80 %RH.
3-1 ACmA (True RMS)
Range
Resolution
Accuracy
50~60 Hz
50~500 Hz
6.000 mA
0.001 mA
1.0% + 8 counts
2.0% + 8 counts
60.00 mA
0.01 mA
1.0% + 5 counts
2.0% + 5 counts
600.0 mA
0.1 mA
Zero correction: Fractions smaller than approximately 0.006 mA are
calibrated to zero.
Low Pass Filter
Range
Resolution
Accuracy
6.000 mA
0.00 1mA
2.0% + 8 counts
60.00 mA
0.01 mA
2.0% + 5 counts
600.0 mA
0.1 mA

Related product manuals