Page 13For technical questions, please call 1-888-866-5797.Item 62380
SAFETYOPERATIONMAINTENANCE SETUP
Emergency Depressurization
If it is necessary to quickly depressurize the Compressor, turn the Power Switch OFF
Then, pull on the ring on the Safety Valve to quickly release stored air pressure�
Automatic Shut off System
1� If the Compressor automatically shuts off
before reaching its normal cutoff pressure:
a� Shut off all tools� Turn power switch off�
b� Wait until the Compressor
cools down (10-20 minutes)�
c� Resume operation�
2� Possible causes of repeated automatic
shut off of the compressor are:
a� Using an extension cord that
is too long or narrow;
b� An air leak or open hose causing the compressor
to cycle too often and build up heat�
3� Correct any issues before further use to
avoid damage to the compressor