1 REVISION 26-AUG-2021
Wellmark Chemical Injection Solutions
11122 WEST LITTLE YORK RD
HOUSTON, TX 77041
Wellmark Website
Wellmark Mobile Support Site
(713) 466-3552
DigiMax Pump Controller
WELLMARK GENERAL PURPOSE DIGIMAX, 12VDC & 115VAC PUMPS
OPERATION/PROGRAMMING INSTRUCTIONS
FEATURES
The DigiMax controller is designed to control chemical injection rates through
intermittent motor control. The 12VDC version is designed to be operated in off-
the-grid battery powered systems for upstream wellsite chemical injection. A
115VAC version is also available for applications where power is available.
Control Features Include
Auto Injection Mode Enter injection rates directly using a
quarts/day input value. The controller will use the physical
characteristics of the pump and motor to determine cycle timing.
Manual Injection Mode Directly enter ON and OFF timing to
manually controller injection rates and cycle timing.
Temperature Injection Includes standard temperature sensor for
temperature-switched injection. Save chemical by disabling flow as
temperatures rise above a user defined setpoint.
Serial Communication Modbus RTU communication via 2-wire
RS485 connection.
Onboard HMI 8x2 LCD screen with 4 capacitive touch sense buttons
for local programming.
Voltage Monitoring (12VDC Versions) Measures voltage
continuously, which may be used to help predict solar application
power failures when connected to a user’s SCADA system.
Cycle Totalizer Totalizes number of cycles ran to help analyze
injection rates. Can be manually reset.
Low Power Screen backlight timeout conserves power when not in
use.
All programming selections made are retained upon power failure. Shutting the
main power switch off, or losing power will not affect controller settings upon
restart.
Contents
Specifications……………………………………………………………………………………….....
1
Basic Operation……………………………………………………………………………………..
1
Viewing Current Settings………………………………………………………………….
1
Setting Injection Mode and Rate……………………………………………………
2
Starting the Pump in Auto Mode………………………………………………
2
Starting the Pump in Manual Mode………………………………………….
2
Pump Override…………………………………………………………………………
2
Advanced Programming……………………………………………………………………………
3
Adjusting Settings in the Programming Sub-Menu……………………......
3
Resetting the Cycle Counter……………………………………………………………..
3
Calibrating Temperature and Voltage……………………………………………….
3
Communication………………………………………………………………………………………
4
Settings…………………………………………………………………………………………….
4
Modbus Map…………………………………………………………………………………….
4
Troubleshooting……………………………………………………………………………………..
4
Replacement Parts……………………………………………………………………………
4
Basic Troubleshooting……………………………………………………………………….
4
Pump Displacement and Timer Settings…………………………………………………….
5
General Pump Specifications…………………………………………………………….
5
Manual Mode On / Off Times…………………………………………….…………….
5
12VDC, 30RPM Small Motor……………………………………………………..
5
12VDC, 64RPM Large Motor………………........................................
6
115VAC, 60 RPM Motor (General Purpose)………………………………..
7
Specifications
Electrical Specifications
Specification
12VDC Control
115VAC Control
Input Voltage
12VDC Nom +/- 3VDC
115VAC, 60Hz, Single
Phase
Max Output Power
180W
345W
Max Current
15A @ 12VDC
3A @ 115VAC
Storage Temp Range
-30C to 70C
Operating
Temperature Range
-20C to 70C
Basic Operation
Viewing Current Settings
The DigiMax controller uses capacitive-sensing buttons. There is no general
contact with the buttons and only requires a light touch. When a button is
pressed the LED above it will illuminate, notifying the user that the input was
registered.
While in normal running mode, the DigiMax will cycle through a series of “Idle
Screens” to display current settings. Idle screens will vary based on the injection
mode settingpressing any of the keys will cycle through the idle screens.
Manual Mode Screens
Auto Mode Screens
MOTOR
Current Cycle ON or OFF Time Remaining (Seconds)
MTR SIZ (Motor Size)
Motor Output Speed (RPMS)
PLG SIZE (Plunger Size)
1/4”, 3/8”, or 1/2” Diameter
PIN POS (Pin Position)
1, 2, or 3
CYCLES
Total Number of Cycles Recorded since Reset
QTS/DAY (Quarts per Day)
Flow Rate Setpoint (Qts/Day)
TEMP MOD (Temperature Mode)
ON (Enabled) or OFF (Disabled)
TEMP SP (Temperature Setpoint)
Setpoint in °F (Current Temp also Displayed in °F)
VOLTAGE*
Current voltage in V
* Voltage output only displayed on 12VDC controllers

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CHAMPIONX WELLMARK DigiMax and is the answer not in the manual?

CHAMPIONX WELLMARK DigiMax Specifications

General IconGeneral
BrandCHAMPIONX
ModelWELLMARK DigiMax
CategoryController
LanguageEnglish