THIS GRILL IS FOR OUTDOOR USE ONLY.
If you have questions or need assistance during assembly, please call .
To insure your satisfaction and for follow-up service, register your grill online at www.grillregistration.com
1-800-241-7548
463268008 • 80065474 • 03-25-08
CAUTION:
Read and follow all safety statements, assembly
instructions, and use and care directions before
attempting to assemble and cook.
INSTALLER/ASSEMBLER:
Leave this manual with consumer.
CONSUMER:
Keep this manual for future reference.
WARNING:
Failure to follow all manufacturer’s instructions could
result in serious personal injury and/or property
damage.
CAUTION:
Some parts may contain sharp edges – especially as
noted in the manual! Wear protective gloves if
necessary.
MODEL 463268008 • PRODUCT GUIDE

Questions and Answers

  • D
    Diana BurnettAug 13, 2025
    What to do if Char-Broil COMMERCIAL 463268008 burner won't match light?
    • M
      Mason AndersonAug 13, 2025
      If the burners on your Char-Broil grill won't match light, make sure you are using a long-stem match (fireplace match). Refer to the “Match-Lighting” section of Use and Care.
  • D
    Diana CampbellAug 17, 2025
    What to do if one burner does not light from other burners on Char-Broil COMMERCIAL 463268008?
    • D
      Denise ToddAug 17, 2025
      If one burner on your Char-Broil grill does not light from the other burners, it is likely due to grease buildup or food particles in the end(s) of the carryover tube(s). Clean the carry-over tube(s) with a wire brush.
  • J
    Joann EllisonAug 21, 2025
    Why is there a sudden drop in gas flow in my Char-Broil Grill?
    • G
      Glen MunozAug 21, 2025
      A sudden drop in gas flow or low flame in your Char-Broil grill can be due to several reasons: you might be out of gas, the excess flow valve may have tripped, or there could be a vapor lock at the coupling nut/LP cylinder connection. To resolve this: * Check the gas level in your LP cylinder. * If the flames are low, turn off the knobs, wait 30 seconds, and then light the grill. If the flames remain low, turn off the knobs and the LP cylinder valve, disconnect the regulator, reconnect it, perform a leak test, turn on the LP cylinder valve, wait 30 seconds, and then light the grill. * Alternatively, turn off the knobs and LP cylinder valve, disconnect the coupling nut from the cylinder, reconnect it, and try again.
  • K
    Kelly MitchellAug 25, 2025
    How to fix flare-ups on Char-Broil Grill?
    • U
      uchambersAug 25, 2025
      Flare-ups on your Char-Broil grill are usually caused by grease buildup, excessive fat in the meat, or excessive cooking temperature. Here's how to address this: * Clean the burners and the inside of the grill/firebox. * Trim the fat from the meat before grilling. * Adjust the cooking temperature accordingly (lower it).
  • K
    Kathryn JonesAug 29, 2025
    What to do if flames blow out on Char-Broil COMMERCIAL 463268008?
    • A
      Anthony CallahanAug 29, 2025
      If the flames on your Char-Broil grill are blowing out, it could be due to high or gusting winds, low LP gas, or a tripped excess flow valve. Try these solutions: * Turn the front of the grill to face the wind or increase the flame height. * Refill the LP cylinder. * Refer to the instructions for a sudden drop in gas flow.
  • J
    Jose HendricksSep 1, 2025
    What causes a persistent grease fire in my Char-Broil COMMERCIAL 463268008 Grill and how to stop it?
    • K
      kingalyssaSep 1, 2025
      A persistent grease fire in your Char-Broil grill is typically caused by grease trapped by food buildup around the burner system. To resolve this: * Turn the knobs to the OFF position. * Turn the gas off at the LP cylinder. * Leave the lid in position and let the fire burn out. * After the grill cools, remove and clean all parts.
  • K
    kristin55Sep 4, 2025
    Why is there a flashback (fire in burner tube(s)) in my Char-Broil Grill?
    • M
      Michael FosterSep 5, 2025
      A flashback, or fire in the burner tubes of your Char-Broil grill, usually means the burner and/or burner tubes are blocked. To fix this: * Turn the knobs to OFF. * Clean the burner and/or burner tubes. See burner cleaning section of Use and Care.
  • J
    Jesse VaughnSep 8, 2025
    Why is my Char-Broil Grill LP cylinder unable to fill?
    • J
      John CordovaSep 8, 2025
      If you're unable to fill your Char-Broil grill's LP cylinder, it might be because some dealers have older fill nozzles with worn threads. These worn nozzles might not have enough "bite" to engage the valve. Try a second LP dealer.

Summary

Use and Care

LP Cylinder Handling and Safety

Proper handling, storage, and safety guidelines for LP cylinders.

LP Cylinder Connection and Leak Testing

Procedures for exchanging, connecting, and leak testing LP cylinders and regulators.

Assembly

Troubleshooting

Emergency Procedures

Actions to take in case of gas leaks, fires, or other critical emergencies.

Common Burner Issues

Diagnosing and resolving problems with ignitor or match lighting of burners.

Gas Flow and Flame Problems

Addressing issues like low gas flow, flames blowing out, flare-ups, and grease fires.

Ignition System Troubleshooting

Detailed steps for diagnosing and fixing electronic ignition system failures.

Limited Warranty

Char-Broil COMMERCIAL 463268008 Specifications

General IconGeneral
TypeGas Grill
Fuel TypePropane
Burners4
MaterialStainless Steel
Side BurnerYes
Dimensions54.1 x 24.5 x 45.5 inches
Primary MaterialStainless Steel
Number of Burners4
Ignition SystemElectronic
Cooking Area650 sq. in.
Ignition TypeElectronic Ignition