Bubble Machine User Manual (Rev. 04) Page 9 of 11
5.
T
ECHNICAL
I
NFORMATION
Product
Maintenance
Dust build up reduces output performance and can cause overheating. This can lead to
reduction of the product’s life and mechanical wear. To maintain optimum performance
and minimize wear, you should clean your products frequently. However, be aware that
usage and environmental conditions could be contributing factors to increase the
cleaning frequency.
After every 40 hours of continuous operation or when the machine will be idle for a long
time it is recommended to rinse the bubble wands and fluid tank with warm water to
prevent a build-up of residue which could reduce performance.
To clean the product, follow the instructions below:
While the unit is unplugged, loosen the thumbscrew and lift cover to reveal the fluid
tank.
Empty all bubble fluid from the tank and replace with warm water.
Plug the product in and allow it to run as usual until all wands appear to be free of
residue.
Always dry the surfaces carefully after cleaning them.
Do not spin the fan using compressed air because you could damage it.
General Troubleshooting
Symptom Possible Cause Possible Action
Circuit breaker or fuse
keeps blowing
Excessive load on the circuit
Make sure that the total load does not
exceed 80% of the breaker or fuse
nominal current
Short circuit along the power lines Check the power lines and power cords
Product does not power
up
No energy on power outlet Check power outlet
Change to another outlet
Loose or damaged power cord Check the power cord
Blown fuse
Replace blown fuse with a good one of
the same type and rating
Internal problem Send product for repair
If you still experience problems after trying the above solutions, contact