WHAT TO DO IF....
28
ENGLISH
Symptom Cause Remedy
The awning closes even
without any wind
blowing.
Low batteries. Open the sensor shell and
deactivate it: if the LED ashes, the
batteries are almost drained. If the
LED is OFF and it does not come
back on, the batteries are dead.
Change the batteries.
Problems with radio
communications.
Check that the sensor is not too
far from the motor or the radio
receiver. Change the position of
the sensor.
Sensor deactivated. The sensor is not active. Perform
the activation procedure again.
The awning motor
does not make its
activation conrmation
movements, when the
shell is snapped onto
the base.
The sensor was not
able to detect a
stable position.
Check the sensor attachment.
Check that the terminal bar is not
vibrating.
The sensor detected
a stable position
before being
snapped into place.
Repeat the activation procedure,
taking care to attach the sensor
within ten seconds of the
conrmation ash.
*Note: for Wave RX motors manufactured before 01/2013
and TDS Gold control units manufactured before 04/2013
the procedure ends without conrmation movements.
By swinging the awning,
the sensor does not
activate closing.
The awning has just been
opened and the stabilization
time is still active.
Open the awning and
wait a few minutes before
performing the test.