4Malfunction codeF4 the indoor fan motor fault
Shut off the power
Take out the plug from the indoor PCB. Then test the
every winding resistance (the normal value: the main
winding is 273Ω. the auxiliary winding is 343Ω) Fig.12
N
The indoor fan motor is bad
then please change it
Y
connect the motor plug with the indoor PCB again and
turn on. Then test the feedback terminal to ground wire
voltage whether it is normal (the normal voltage is
increased gradually from 0 to +2.4VDC) Fig.10
N
The indoor fan motor is badthen
please change it
Y
The indoor PCB is bad. Please change it
Check the indoor fan whether it is smooth
N
1. If the fan is bad and change it
2. The bolt what fix the indoor fan is
loose. Please screw it again
3. There are any dirt in the indoor
fan. Please clean it
Y
The faulty cause
1the fan motor is blocked or turns
abnormally
2the motor wire is loose or contacts
ill
3the indoor fan motor has been
damaged
4the indoor PCB is bad
Fig. 12the indoor fan motor
The main winding resistance the motor wire:
black-white 273Ω) the auxiliary winding resistance
the motor wire: red-white 343Ω)