The spring gasket
Fig. 30.The damaged spring gasket
Fig. 31 .The spring gasket is in good condition.
Fig. 28.1 The indoor
evaporator’s middle
temp sensor (pipe
number: 3)
Fig. 28.2 The indoor
evaporator’s inlet temp
senso
r
(p
i
p
e number: 4
)
Fig.28.3 The indoor
evaporator’s inlet temp
sensor (pipe number: 2)
Fig. 29 The indoor
ambient temp sensor
p
i
p
e numbe
r
1
Note: Apart from the ambient
temperature sensor, all sensors must
be equipped with spring washer,
please check it by Fig. If the angle is
similar to Fig. 24, means that spring
has lost its elasticity .please bend it to
an angle of 135 degrees, Re. Fig. 8;
Please ensure to install them if no
spring washer,.