12The malfunction code: FF (The outdoor unit fault)
Fig.32 the DC motor
Turn off the power
Check the resistance value of the motor each port are normal.
The reference resistance value of motor port.(Vm-GND
Vcc-GND 125kVsp-GND 200kPG-GND )
N
The motor is bad or there is trouble
in the circuit. Please change it
Y
Power up and turn on the unit, check motor port
voltage value whether the VCC and Vm are
normal (the normal voltage value:VCC:15Vdc
Vm/P:340VdcVsp:0~5V)
Refer to Fig. 32
Y
The outdoor PCB is bad. Please
change it
The motor circuit is bad. Please change this
motor
N
The faulty cause
1 The motor is bad or there is
trouble in the indoor PCB
2 The outdoor PCB is bad
3 Motor is bad
The reference resistance value of motor
port.(Vm-GND ∞, Vcc-GND 125kΩ,
Vsp-GND 200kΩ,PG-GND )